Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
239
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0186 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,550 | $30 | Not Implemented |
UL0186 # 04 Y:1997 | 04 | 1997 | METER WASTE WATER | $53,265 | $4,500 | Not Implemented |
UL0186 # 05 Y:1997 | 05 | 1997 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $2,560 | $600 | Not Implemented |
UL0186 # 06 Y:1997 | 06 | 1997 | CLEAR AND RENT EXISTING SPACE | $1,880,000 | $0 | Not Implemented |
UL0180 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $135 | $3,650 | Not Implemented |
UL0180 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $2,813 | Implemented |
UL0180 # 03 Y:1997 | 03 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $526 | $87 | Not Implemented |
UL0180 # 04 Y:1997 | 04 | 1997 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $8,150 | $0 | Implemented |
UL0180 # 05 Y:1997 | 05 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,000 | $17,500 | Implemented |
UL0180 # 06 Y:1997 | 06 | 1997 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $19,400 | $3,600 | Implemented |
UL0174 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $606 | $3,052 | Not Implemented |
UL0174 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $185 | $5,640 | Implemented |
UL0174 # 03 Y:1996 | 03 | 1996 | OPTIMIZE PLANT POWER FACTOR | $54,283 | $26,194 | Implemented |
UL0174 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $872 | $20 | Not Implemented |
UL0174 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $550 | $0 | Not Implemented |
UL0174 # 06 Y:1996 | 06 | 1996 | RECYCLE CLEANING SOLVENT AND REUSE | $6,760 | $9,845 | Implemented |
UL0174 # 07 Y:1996 | 07 | 1996 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $7,302 | $2,536 | Not Implemented |
UL0171 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $100 | $3,020 | Implemented |
UL0171 # 02 Y:1996 | 02 | 1996 | OPTIMIZE PLANT POWER FACTOR | $5,423 | $6,179 | Implemented |
UL0171 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $195 | $20 | Not Implemented |
UL0171 # 04 Y:1996 | 04 | 1996 | RECOVER AND REUSE WASTE MATERIAL | $1,860 | $0 | Not Implemented |
UL0171 # 05 Y:1996 | 05 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $20,800 | $0 | Implemented |
UL0171 # 06 Y:1996 | 06 | 1996 | WASH AND REUSE RAGS ON-SITE | $29,350 | $4,300 | Not Implemented |
UL0173 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40 | $537 | Not Implemented |
UL0173 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,502 | $500 | Not Implemented |