Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
239
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0173 # 03 Y:1996 | 03 | 1996 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $49 | $0 | Implemented |
UL0173 # 04 Y:1996 | 04 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $100 | $190 | Not Implemented |
UL0173 # 05 Y:1996 | 05 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $393 | $0 | Not Implemented |
UL0173 # 06 Y:1996 | 06 | 1996 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $15,930 | $7,600 | Implemented |
UL0168 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,936 | $1,400 | Implemented |
UL0168 # 02 Y:1996 | 02 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $960 | $40 | Implemented |
UL0168 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,464 | $35 | Implemented |
UL0168 # 04 Y:1996 | 04 | 1996 | OPTIMIZE PLANT POWER FACTOR | $2,820 | $7,774 | Not Implemented |
UL0168 # 05 Y:1996 | 05 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $459 | $200 | Not Implemented |
UL0168 # 06 Y:1996 | 06 | 1996 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $265 | $265 | Not Implemented |
UL0168 # 07 Y:1996 | 07 | 1996 | REGENERATE CLEANING SOLVENT ON-SITE AND REUSE | $17,338 | $3,000 | Not Implemented |
UL0168 # 08 Y:1996 | 08 | 1996 | USE EVAPORATION TO CONCENTRATE MATERIAL | $16,800 | $5,070 | Implemented |
UL0163 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $175 | $4,910 | Implemented |
UL0163 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,025 | $1,122 | Implemented |
UL0163 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $693 | $60 | Implemented |
UL0163 # 04 Y:1996 | 04 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,710 | $0 | Not Implemented |
UL0163 # 05 Y:1996 | 05 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $156,073 | $61,000 | Implemented |
UL0164 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $278 | $11,520 | Implemented |
UL0164 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,091 | $2,901 | Implemented |
UL0164 # 03 Y:1996 | 03 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $984 | $60 | Implemented |
UL0164 # 04 Y:1996 | 04 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,547 | $0 | Not Implemented |
UL0164 # 05 Y:1996 | 05 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $40,316 | $31,000 | Implemented |
UL0165 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $489 | $795 | Implemented |
UL0165 # 02 Y:1996 | 02 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $135 | $40 | Implemented |
UL0165 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $197 | $3,920 | Implemented |