Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,732
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0417 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $2,390 | $3,500 | Not Implemented |
UM0417 # 03 Y:2012 | 03 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,907 | $5,000 | Not Implemented |
UM0417 # 04 Y:2012 | 04 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,038 | $200 | Not Implemented |
UM0417 # 05 Y:2012 | 05 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $6,000 | $200 | Implemented |
UM0417 # 06 Y:2012 | 06 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $305 | $100 | Not Implemented |
UM0417 # 07 Y:2012 | 07 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,464 | $35,000 | Not Implemented |
UM0417 # 08 Y:2012 | 08 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,721 | $500 | Not Implemented |
UMS013 # 05 Y:2012 | 05 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $137,000 | $0 | Not Implemented |
UMS013 # 04 Y:2012 | 04 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $465,000 | $700,000 | Not Implemented |
UMS013 # 03 Y:2012 | 03 | 2012 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $673,000 | $1,000,000 | Not Implemented |
UMS013 # 02 Y:2012 | 02 | 2012 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $106,000 | $200,000 | Not Implemented |
UMS013 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $320,000 | $600,000 | Not Implemented |
UMS012 # 02 Y:2012 | 02 | 2012 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $553,000 | $750,000 | Not Implemented |
UMS012 # 01 Y:2012 | 01 | 2012 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $347,000 | $600,000 | Not Implemented |
UM0415 # 01 Y:2012 | 01 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,072 | $4,000 | Not Implemented |
UM0415 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $822 | $875 | Implemented |
UM0415 # 03 Y:2012 | 03 | 2012 | OPTIMIZE PLANT POWER FACTOR | $12,081 | $20,000 | Not Implemented |
UM0415 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,832 | $10,965 | Not Implemented |
UM0415 # 05 Y:2012 | 05 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $23,600 | $1,000 | Implemented |
UM0415 # 06 Y:2012 | 06 | 2012 | INSULATE BARE EQUIPMENT | $1,697 | $1,500 | Not Implemented |
UM0414 # 01 Y:2012 | 01 | 2012 | REDUCE VENTILATION AIR | $15,347 | $20,200 | Not Implemented |
UM0414 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,787 | $200 | Not Implemented |
UM0414 # 03 Y:2012 | 03 | 2012 | OPTIMIZE PLANT POWER FACTOR | $6,520 | $10,000 | Not Implemented |
UM0414 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $449 | $100 | Not Implemented |
UM0414 # 05 Y:2012 | 05 | 2012 | REDUCE VENTILATION AIR | $9,526 | $0 | Not Implemented |