Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
159
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0147 # 04 Y:1999 | 04 | 1999 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,215 | $10,000 | Not Implemented |
UM0147 # 02 Y:1999 | 02 | 1999 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,796 | $2,000 | Not Implemented |
UM0147 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,038 | $3,557 | Not Implemented |
UM0146 # 06 Y:1999 | 06 | 1999 | $6,000 | $3,600 | Not Implemented | |
UM0146 # 03 Y:1999 | 03 | 1999 | INSULATE BARE EQUIPMENT | $2,510 | $200 | Not Implemented |
UM0146 # 05 Y:1999 | 05 | 1999 | USE A RAG RECYCLE SERVICE | $925 | $0 | Not Implemented |
UM0146 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $78 | $200 | Not Implemented |
UM0146 # 04 Y:1999 | 04 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $15,807 | $40,000 | Not Implemented |
UM0146 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,736 | $220 | Not Implemented |
UM0146 # 07 Y:1999 | 07 | 1999 | $11,207 | $40,000 | Not Implemented | |
UM0145 # 06 Y:1999 | 06 | 1999 | USE ABSORPTION, EXTRACTION TO REMOVE CONTAMINANTS | $24,222 | $60,000 | Implemented |
UM0145 # 01 Y:1999 | 01 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,720 | $300 | Implemented |
UM0145 # 07 Y:1999 | 07 | 1999 | $16,869 | $14,495 | Implemented | |
UM0145 # 04 Y:1999 | 04 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,978 | $11,600 | Not Implemented |
UM0145 # 02 Y:1999 | 02 | 1999 | USE RADIANT HEATER FOR SPOT HEATING | $2,157 | $4,500 | Not Implemented |
UM0145 # 05 Y:1999 | 05 | 1999 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $50,143 | $85,000 | Not Implemented |
UM0145 # 03 Y:1999 | 03 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,970 | $40,000 | Not Implemented |
UM0145 # 08 Y:1999 | 08 | 1999 | $32,500 | $2,000 | Not Implemented | |
UM0144 # 06 Y:1999 | 06 | 1999 | REDUCE SCRAP PRODUCTION | $29,091 | $5,000 | Implemented |
UM0144 # 07 Y:1999 | 07 | 1999 | $7,680 | $584 | Implemented | |
UM0144 # 01 Y:1999 | 01 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,661 | $110 | Implemented |
UM0144 # 05 Y:1999 | 05 | 1999 | USE OPTIMUM THICKNESS INSULATION | $1,848 | $2,100 | Not Implemented |
UM0144 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $647 | $1,000 | Implemented |
UM0144 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,285 | $350 | Implemented |
UM0144 # 04 Y:1999 | 04 | 1999 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $5,837 | $9,350 | Not Implemented |