IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

278

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0199 # 01 Y:2002 01 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $154,000 $154,000 Not Implemented
UM0199 # 02 Y:2002 02 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $166,000 $437,500 Not Implemented
UM0199 # 03 Y:2002 03 2002 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,300 $5,000 Not Implemented
UM0188 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,363 $1,083 Not Implemented
UM0188 # 02 Y:2001 02 2001 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,080 $500 Not Implemented
UM0188 # 03 Y:2001 03 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $12,400 $2,800 Not Implemented
UM0188 # 04 Y:2001 04 2001 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $263 $1,020 Not Implemented
UM0188 # 05 Y:2001 05 2001 INSTALL AN UNINTERUPTABLE POWER SUPPLY $3,333 $1,500 Implemented
UM0185 # 01 Y:2001 01 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,400 $600 Implemented
UM0185 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,546 $450 Implemented
UM0185 # 03 Y:2001 03 2001 OPTIMIZE PLANT POWER FACTOR $4,605 $24,000 Not Implemented
UM0185 # 04 Y:2001 04 2001 COVER OPEN TANKS $13,500 $12,000 Not Implemented
UM0185 # 05 Y:2001 05 2001 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $50,525 $10,000 Implemented
UM0185 # 06 Y:2001 06 2001 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $126,200 $115,000 Not Implemented
UM0185 # 07 Y:2001 07 2001 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $28,800 $30,000 Not Implemented
UM0183 # 01 Y:2001 01 2001 USE CORRECT SIZE STEAM TRAPS $2,880 $2,500 n/a
UM0183 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $1,400 $1,200 n/a
UM0183 # 03 Y:2001 03 2001 UTILIZE A LESS EXPENSIVE COOLING METHOD $700 $3,000 n/a
UM0183 # 04 Y:2001 04 2001 TREAT AND REUSE RINSE WATERS $780 $1,000 n/a
UM0183 # 05 Y:2001 05 2001 MINIMIZE WATER USAGE $2,400 $5,000 n/a
UM0183 # 06 Y:2001 06 2001 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE $4,900 $7,400 n/a
UM0183 # 07 Y:2001 07 2001 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $2,500 $1,000 n/a
UM0183 # 08 Y:2001 08 2001 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $10,800 $14,400 n/a
UM0150 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,828 $1,500 Not Implemented
UM0150 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $680 $300 Implemented