Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,600
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UU0241 # 02 Y:2024 | 02 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,030 | $17,040 | n/a |
UU0241 # 01 Y:2024 | 01 | 2024 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $8,700 | $12,200 | n/a |
UU0242 # 01 Y:2024 | 01 | 2024 | TURN OFF EQUIPMENT WHEN NOT IN USE | $139,774 | $4,000 | n/a |
UU0242 # 03 Y:2024 | 03 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,164 | $37,300 | n/a |
UU0242 # 02 Y:2024 | 02 | 2024 | CLOSE OFF UNNEEDED STEAM LINES | $10,220 | $4,400 | n/a |
UU0242 # 04 Y:2024 | 04 | 2024 | INSTALL OCCUPANCY SENSORS | $5,187 | $5,143 | n/a |
UU0242 # 05 Y:2024 | 05 | 2024 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,004 | $11,422 | n/a |
UU0242 # 06 Y:2024 | 06 | 2024 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $21,730 | $82,100 | n/a |
UU0242 # 07 Y:2024 | 07 | 2024 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,520 | $9,510 | n/a |
UU0242 # 08 Y:2024 | 08 | 2024 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,658 | $13,800 | n/a |
UU0242 # 09 Y:2024 | 09 | 2024 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,487 | $68,600 | n/a |
UU0242 # 10 Y:2024 | 10 | 2024 | UPGRADE OBSOLETE EQUIPMENT | $12,250 | $84,300 | n/a |
UU0245 # 01 Y:2024 | 01 | 2024 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $13,514 | $18,000 | n/a |
UU0245 # 02 Y:2024 | 02 | 2024 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,693 | $25,330 | n/a |
UU0245 # 03 Y:2024 | 03 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,961 | $3,200 | n/a |
UU0245 # 04 Y:2024 | 04 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $299 | $100 | n/a |
UU0244 # 01 Y:2024 | 01 | 2024 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,850 | $2,400 | n/a |
UU0244 # 02 Y:2024 | 02 | 2024 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $3,681 | $3,450 | n/a |
UU0244 # 03 Y:2024 | 03 | 2024 | INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE | $370 | $264 | n/a |
UU0244 # 04 Y:2024 | 04 | 2024 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $307 | $460 | n/a |
UU0243 # 07 Y:2024 | 07 | 2024 | OPTIMIZE PLANT POWER FACTOR | $1,900 | $6,000 | n/a |
UU0243 # 06 Y:2024 | 06 | 2024 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,800 | $6,300 | n/a |
UU0243 # 05 Y:2024 | 05 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,244 | $14,145 | n/a |
UU0243 # 04 Y:2024 | 04 | 2024 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,631 | $22,338 | n/a |
UU0243 # 03 Y:2024 | 03 | 2024 | COVER OPEN TANKS | $9,190 | $7,340 | n/a |