Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0493 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,969 | $2,000 | Not Implemented |
WI0492 # 01 Y:2005 | 01 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,385 | $25,200 | Implemented |
WI0492 # 02 Y:2005 | 02 | 2005 | USE EVAPORATION TO CONCENTRATE MATERIAL | $10,448 | $8,000 | Not Implemented |
WI0492 # 03 Y:2005 | 03 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,782 | $4,300 | Not Implemented |
WI0492 # 04 Y:2005 | 04 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $5,832 | $1,000 | Implemented |
WI0492 # 05 Y:2005 | 05 | 2005 | IMPROVE LUBRICATION PRACTICES | $3,033 | $2,155 | Implemented |
WI0492 # 06 Y:2005 | 06 | 2005 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,820 | $0 | Not Implemented |
WI0492 # 07 Y:2005 | 07 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $1,494 | $600 | Implemented |
WI0492 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,335 | $1,280 | Implemented |
WI0492 # 09 Y:2005 | 09 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $665 | $800 | Not Implemented |
WI0491 # 01 Y:2005 | 01 | 2005 | INSTALL DESICCANT HUMIDITY CONTROL SYSTEM | $23,636 | $25,000 | Not Implemented |
WI0491 # 02 Y:2005 | 02 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $12,939 | $15,000 | Not Implemented |
WI0491 # 03 Y:2005 | 03 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,911 | $5,000 | Implemented |
WI0491 # 04 Y:2005 | 04 | 2005 | IMPROVE LUBRICATION PRACTICES | $1,322 | $2,340 | Not Implemented |
WI0491 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,112 | $1,680 | Implemented |
WI0491 # 06 Y:2005 | 06 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $706 | $1,244 | Implemented |
WI0490 # 01 Y:2005 | 01 | 2005 | IMPROVE SPACE COMFORT CONDITIONING | $260,463 | $360,000 | Not Implemented |
WI0490 # 02 Y:2005 | 02 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $85,979 | $75,000 | Not Implemented |
WI0490 # 03 Y:2005 | 03 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $7,000 | $1,000 | Implemented |
WI0490 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,347 | $18,900 | Not Implemented |
WI0490 # 05 Y:2005 | 05 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $617 | $640 | Not Implemented |
WI0490 # 06 Y:2005 | 06 | 2005 | IMPROVE LUBRICATION PRACTICES | $538 | $1,165 | Implemented |
WI0490 # 07 Y:2005 | 07 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $361 | $0 | Implemented |
WI0490 # 08 Y:2005 | 08 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $317 | $227 | Implemented |
WI0490 # 09 Y:2005 | 09 | 2005 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $316 | $52 | Implemented |