Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0415 # 04 Y:2002 | 04 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,616 | $0 | Not Implemented |
WI0415 # 05 Y:2002 | 05 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,252 | $1,086 | Implemented |
WI0415 # 06 Y:2002 | 06 | 2002 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $737 | $0 | Not Implemented |
WI0415 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $307 | $68 | Implemented |
WI0414 # 01 Y:2002 | 01 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,469 | $1,800 | Not Implemented |
WI0414 # 02 Y:2002 | 02 | 2002 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $6,619 | $14,000 | Not Implemented |
WI0414 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,225 | $0 | Implemented |
WI0414 # 04 Y:2002 | 04 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,730 | $0 | Implemented |
WI0414 # 05 Y:2002 | 05 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,560 | $1,033 | Not Implemented |
WI0414 # 06 Y:2002 | 06 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,971 | $0 | Not Implemented |
WI0414 # 07 Y:2002 | 07 | 2002 | INSTALL OCCUPANCY SENSORS | $1,071 | $2,400 | Implemented |
WI0414 # 08 Y:2002 | 08 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $754 | $350 | Implemented |
WI0413 # 01 Y:2002 | 01 | 2002 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $27,075 | $130,000 | Not Implemented |
WI0413 # 02 Y:2002 | 02 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,951 | $3,762 | Not Implemented |
WI0413 # 03 Y:2002 | 03 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,493 | $600 | Not Implemented |
WI0413 # 04 Y:2002 | 04 | 2002 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $6,626 | $26,500 | n/a |
WI0413 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,732 | $25,405 | n/a |
WI0413 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $928 | $640 | Implemented |
WI0412 # 01 Y:2002 | 01 | 2002 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,881 | $1,200 | Implemented |
WI0412 # 02 Y:2002 | 02 | 2002 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $8,966 | $11,000 | Not Implemented |
WI0412 # 03 Y:2002 | 03 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,780 | $0 | Not Implemented |
WI0412 # 04 Y:2002 | 04 | 2002 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $3,383 | $10,000 | n/a |
WI0412 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,774 | $90 | Implemented |
WI0412 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $1,656 | $9,500 | Not Implemented |
WI0412 # 07 Y:2002 | 07 | 2002 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,047 | $1,050 | Implemented |