Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0328 # 06 Y:1998 | 06 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $287 | $820 | Not Implemented |
WI0328 # 07 Y:1998 | 07 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $726 | $200 | Not Implemented |
WI0328 # 08 Y:1998 | 08 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $380 | $840 | Implemented |
WI0327 # 01 Y:1998 | 01 | 1998 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $13,100 | $0 | Not Implemented |
WI0327 # 02 Y:1998 | 02 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $7,343 | $0 | Not Implemented |
WI0327 # 03 Y:1998 | 03 | 1998 | INSTALL OCCUPANCY SENSORS | $4,466 | $7,200 | Not Implemented |
WI0327 # 04 Y:1998 | 04 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,266 | $9,500 | Not Implemented |
WI0327 # 05 Y:1998 | 05 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $528 | $800 | Implemented |
WI0327 # 06 Y:1998 | 06 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,573 | $590 | Implemented |
WI0327 # 07 Y:1998 | 07 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $701 | $0 | Not Implemented |
WI0327 # 08 Y:1998 | 08 | 1998 | DISCONNECT BALLASTS | $487 | $0 | Not Implemented |
WI0326 # 01 Y:1998 | 01 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $52,640 | $25,000 | Not Implemented |
WI0326 # 02 Y:1998 | 02 | 1998 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $43,913 | $40,000 | Not Implemented |
WI0326 # 03 Y:1998 | 03 | 1998 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $11,269 | $20,000 | Not Implemented |
WI0326 # 04 Y:1998 | 04 | 1998 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $7,874 | $12,186 | Not Implemented |
WI0326 # 05 Y:1998 | 05 | 1998 | USE A RAG RECYCLE SERVICE | $4,430 | $0 | Not Implemented |
WI0326 # 06 Y:1998 | 06 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,348 | $12,500 | Not Implemented |
WI0326 # 07 Y:1998 | 07 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,948 | $740 | Not Implemented |
WI0326 # 08 Y:1998 | 08 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $504 | $400 | Not Implemented |
WI0326 # 09 Y:1998 | 09 | 1998 | INSULATE BARE EQUIPMENT | $321 | $46 | Not Implemented |
WI0326 # 10 Y:1998 | 10 | 1998 | REMOVE SLUDGE FROM TANKS ON A REGULAR BASIS | $300 | $0 | Not Implemented |
WI0325 # 01 Y:1998 | 01 | 1998 | INSTALL AUTOMATIC PACKING EQUIPMENT | $336,000 | $240,000 | Not Implemented |
WI0325 # 02 Y:1998 | 02 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,848 | $500 | Implemented |
WI0325 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,598 | $10,000 | Not Implemented |
WI0325 # 04 Y:1998 | 04 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,590 | $0 | Not Implemented |