Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
72
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0562 # 07 Y:2018 | 07 | 2018 | MINIMIZE WATER USAGE | $543 | $2,100 | Implemented |
WV0562 # 06 Y:2018 | 06 | 2018 | INSULATE BARE EQUIPMENT | $2,979 | $1,328 | Implemented |
WV0562 # 05 Y:2018 | 05 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $6,713 | $703 | Implemented |
WV0562 # 04 Y:2018 | 04 | 2018 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $10,822 | $0 | Implemented |
WV0562 # 03 Y:2018 | 03 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,359 | $2,000 | Implemented |
WV0562 # 02 Y:2018 | 02 | 2018 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,104 | $80,009 | Not Implemented |
WV0562 # 01 Y:2018 | 01 | 2018 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $284,971 | $600,000 | Not Implemented |
WV0559 # 06 Y:2018 | 06 | 2018 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $2,563 | $11,400 | Not Implemented |
WV0559 # 09 Y:2018 | 09 | 2018 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $681 | $3,000 | Not Implemented |
WV0559 # 08 Y:2018 | 08 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $2,043 | $721 | Implemented |
WV0559 # 07 Y:2018 | 07 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,998 | $7,133 | Implemented |
WV0559 # 05 Y:2018 | 05 | 2018 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $4,560 | $1,000 | Implemented |
WV0559 # 04 Y:2018 | 04 | 2018 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $4,668 | $19,300 | Implemented |
WV0559 # 03 Y:2018 | 03 | 2018 | INSTALL OCCUPANCY SENSORS | $6,517 | $3,640 | Implemented |
WV0559 # 02 Y:2018 | 02 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $45,746 | $111,500 | Not Implemented |
WV0559 # 01 Y:2018 | 01 | 2018 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $84,000 | $3,000 | Implemented |
WV0558 # 08 Y:2018 | 08 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $522 | Implemented |
WV0558 # 07 Y:2018 | 07 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $406 | $2,005 | Not Implemented |
WV0558 # 06 Y:2018 | 06 | 2018 | DEVELOP A REPAIR/REPLACE POLICY | $629 | $579 | Implemented |
WV0558 # 05 Y:2018 | 05 | 2018 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $1,726 | $7,488 | Implemented |
WV0558 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $2,061 | $1,265 | Not Implemented |
WV0558 # 03 Y:2018 | 03 | 2018 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,223 | $1,000 | Implemented |
WV0558 # 02 Y:2018 | 02 | 2018 | PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT | $10,332 | $20,570 | Not Implemented |
WV0558 # 01 Y:2018 | 01 | 2018 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $17,760 | $81,750 | Not Implemented |
WV0556 # 06 Y:2018 | 06 | 2018 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,985 | $222 | Implemented |