Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
308
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0222 # 04 Y:2001 | 04 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,685 | $880 | Implemented |
WV0222 # 03 Y:2001 | 03 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,296 | $1,000 | Implemented |
WV0222 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $935 | $100 | Implemented |
WV0222 # 01 Y:2001 | 01 | 2001 | USE COOLING AIR WHICH COOLS HOT WORK PIECES FOR SPACE HEATING | $16,581 | $2,904 | Not Implemented |
WV0221 # 04 Y:2001 | 04 | 2001 | OPTIMIZE PLANT POWER FACTOR | $11,836 | $8,422 | Implemented |
WV0221 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,200 | $3,420 | Implemented |
WV0221 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $394 | $60 | Implemented |
WV0221 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $8,016 | $866 | Implemented |
WV0221 # 05 Y:2001 | 05 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $12,579 | $1,200 | Implemented |
WV0221 # 06 Y:2001 | 06 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,330 | $3,980 | Implemented |
WV0221 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,986 | $600 | Implemented |
WV0221 # 07 Y:2001 | 07 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $14,790 | $1,000 | Implemented |
WV0221 # 09 Y:2001 | 09 | 2001 | RECYCLE FLUORESCENT LAMPS | $3,048 | $320 | Not Implemented |
WV0221 # 10 Y:2001 | 10 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $11,038 | $2,000 | Implemented |
WV0221 # 11 Y:2001 | 11 | 2001 | $15,000 | $6,000 | Not Implemented | |
WV0220 # 06 Y:2001 | 06 | 2001 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,872 | $1,457 | Not Implemented |
WV0220 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,623 | $3,010 | Implemented |
WV0220 # 02 Y:2001 | 02 | 2001 | USE PHOTOCELL CONTROLS | $432 | $300 | Implemented |
WV0220 # 03 Y:2001 | 03 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,633 | $540 | Implemented |
WV0220 # 04 Y:2001 | 04 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $804 | $54 | Implemented |
WV0220 # 05 Y:2001 | 05 | 2001 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $241 | $36 | Implemented |
WV0220 # 07 Y:2001 | 07 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,626 | $190 | Implemented |
WV0220 # 13 Y:2001 | 13 | 2001 | $110,160 | $63,182 | Not Implemented | |
WV0220 # 12 Y:2001 | 12 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $5,188 | $7,000 | Not Implemented |
WV0220 # 11 Y:2001 | 11 | 2001 | BURN WASTE OIL FOR HEAT | $3,635 | $4,700 | Not Implemented |