Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,492
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0233 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,837 | $3,400 | Implemented |
LL0233 # 09 Y:2005 | 09 | 2005 | USE PHOTOCELL CONTROLS | $2,451 | $450 | Implemented |
LL0232 # 03 Y:2005 | 03 | 2005 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $44,802 | $20,000 | Implemented |
LL0232 # 04 Y:2005 | 04 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $43,777 | $6,100 | Implemented |
LL0232 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $35,683 | $27,760 | Implemented |
LL0232 # 07 Y:2005 | 07 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,717 | $2,000 | Implemented |
LL0232 # 08 Y:2005 | 08 | 2005 | AIR CONDITION ONLY SPACE NECESSARY | $5,876 | $60 | Implemented |
LL0232 # 09 Y:2005 | 09 | 2005 | USE PHOTOCELL CONTROLS | $2,101 | $700 | Implemented |
LL0232 # 12 Y:2005 | 12 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,185 | $1,120 | Implemented |
LL0232 # 13 Y:2005 | 13 | 2005 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,350 | $3,010 | Implemented |
MS0272 # 03 Y:2005 | 03 | 2005 | PAY UTILITY BILLS ON TIME | $783 | $0 | Implemented |
MS0272 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $569 | $151 | Implemented |
MS0272 # 06 Y:2005 | 06 | 2005 | DISCONNECT BALLASTS | $153 | $216 | Implemented |
MS0272 # 07 Y:2005 | 07 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $95 | $19 | Implemented |
OK0693 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,903 | $31,913 | Implemented |
OK0693 # 08 Y:2004 | 08 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $772 | $1,140 | Implemented |
OK0693 # 09 Y:2004 | 09 | 2004 | INSTALL OCCUPANCY SENSORS | $356 | $737 | Implemented |
LL0192 # 01 Y:2004 | 01 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $61,254 | $2,590 | Implemented |
LL0192 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $41,577 | $4,400 | Implemented |
LL0192 # 05 Y:2004 | 05 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,708 | $2,585 | Implemented |
OK0692 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,239 | $2,275 | Implemented |
OK0692 # 04 Y:2004 | 04 | 2004 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,221 | $8,625 | Implemented |
OK0692 # 06 Y:2004 | 06 | 2004 | INSTALL SET-BACK TIMERS | $81,447 | $10,000 | Implemented |
OK0692 # 07 Y:2004 | 07 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $8,800 | $0 | Implemented |
OK0692 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,577 | $11,882 | Implemented |