Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73,576
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0073 # 09 Y:1989 | 09 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $236 | $0 | Implemented |
WI0075 # 01 Y:1989 | 01 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,157 | $3,100 | Implemented |
WI0075 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $898 | $250 | Implemented |
WI0075 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $227 | $104 | Implemented |
WI0075 # 06 Y:1989 | 06 | 1989 | INSTALL STORM WINDOWS AND DOORS | $671 | $1,144 | Implemented |
WI0075 # 09 Y:1989 | 09 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $245 | $165 | Implemented |
OK0302 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $484 | $167 | Implemented |
OK0302 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $134 | $280 | Implemented |
OK0302 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $373 | $630 | Implemented |
OK0299 # 01 Y:1989 | 01 | 1989 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $7,885 | $23,283 | Implemented |
OK0299 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $566 | $783 | Implemented |
CO0165 # 02 Y:1989 | 02 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,307 | $250 | Implemented |
CO0165 # 04 Y:1989 | 04 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,603 | $1,850 | Implemented |
CO0165 # 05 Y:1989 | 05 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,040 | $3,000 | Implemented |
CO0165 # 08 Y:1989 | 08 | 1989 | REDUCE VENTILATION AIR | $710 | $450 | Implemented |
CO0165 # 09 Y:1989 | 09 | 1989 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $418 | $300 | Implemented |
CO0166 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,860 | $250 | Implemented |
CO0166 # 02 Y:1989 | 02 | 1989 | OPTIMIZE PLANT POWER FACTOR | $3,760 | $3,900 | Implemented |
CO0166 # 03 Y:1989 | 03 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $2,050 | $4,000 | Implemented |
CO0166 # 05 Y:1989 | 05 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $800 | $600 | Implemented |
CO0166 # 07 Y:1989 | 07 | 1989 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $430 | $100 | Implemented |
CO0167 # 01 Y:1989 | 01 | 1989 | OPTIMIZE PLANT POWER FACTOR | $6,740 | $6,800 | Implemented |
CO0167 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,010 | $150 | Implemented |
CO0167 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $455 | $335 | Implemented |
CO0167 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $105 | $315 | Implemented |