Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
73,539
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0277 # 02 Y:1986 | 02 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,442 | $150 | Implemented |
TN0277 # 03 Y:1986 | 03 | 1986 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,251 | $500 | Implemented |
TN0277 # 04 Y:1986 | 04 | 1986 | REPAIR AND ELIMINATE STEAM LEAKS | $2,016 | $125 | Implemented |
TN0277 # 07 Y:1986 | 07 | 1986 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $826 | $1,700 | Implemented |
TN0277 # 08 Y:1986 | 08 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $396 | $0 | Implemented |
TN0277 # 09 Y:1986 | 09 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $661 | $440 | Implemented |
TN0277 # 10 Y:1986 | 10 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $149 | $220 | Implemented |
UD0213 # 01 Y:1987 | 01 | 1987 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,229 | $20,000 | Implemented |
UD0213 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,000 | $10,000 | Implemented |
UD0213 # 04 Y:1987 | 04 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,036 | $2,000 | Implemented |
UD0213 # 05 Y:1987 | 05 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,181 | $15,000 | Implemented |
UD0214 # 02 Y:1987 | 02 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,230 | $800 | Implemented |
UD0214 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,924 | $910 | Implemented |
UD0215 # 01 Y:1987 | 01 | 1987 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $4,028 | $0 | Implemented |
UD0215 # 02 Y:1987 | 02 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $662 | $140 | Implemented |
UD0215 # 04 Y:1987 | 04 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $265 | $300 | Implemented |
ST0072 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,729 | $90 | Implemented |
ST0072 # 02 Y:1986 | 02 | 1986 | RECOVER WASTE HEAT FROM EQUIPMENT | $698 | $1,000 | Implemented |
ST0072 # 03 Y:1986 | 03 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $807 | $537 | Implemented |
ST0072 # 04 Y:1986 | 04 | 1986 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $1,017 | $0 | Implemented |
ST0072 # 06 Y:1986 | 06 | 1986 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $20,785 | $36,000 | Implemented |
ST0072 # 07 Y:1986 | 07 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,345 | $813 | Implemented |
ST0072 # 08 Y:1986 | 08 | 1986 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $463 | $486 | Implemented |
ST0073 # 01 Y:1986 | 01 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,796 | $80 | Implemented |
ST0073 # 02 Y:1986 | 02 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,101 | $0 | Implemented |