Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
276
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0080 # 01 Y:2016 | 01 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,244 | $1,250 | Implemented |
BS0077 # 09 Y:2016 | 09 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $167 | $400 | Implemented |
BS0077 # 07 Y:2016 | 07 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $118 | $47 | Implemented |
BS0077 # 06 Y:2016 | 06 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $370 | $15 | Implemented |
BS0077 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,328 | $3,080 | Implemented |
BS0077 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $711 | $960 | Implemented |
BS0077 # 02 Y:2016 | 02 | 2016 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $698 | $505 | Implemented |
BS0075 # 06 Y:2016 | 06 | 2016 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $73,741 | $24,334 | Implemented |
BS0075 # 05 Y:2016 | 05 | 2016 | MINIMIZE WATER USAGE | $256 | $53 | Implemented |
BS0075 # 04 Y:2016 | 04 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $7,616 | $3,250 | Implemented |
BS0075 # 03 Y:2016 | 03 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $146 | $52 | Implemented |
BS0075 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $513 | $502 | Implemented |
BS0075 # 01 Y:2016 | 01 | 2016 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,685 | $1,464 | Implemented |
BS0074 # 09 Y:2016 | 09 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $177 | $483 | Implemented |
BS0074 # 08 Y:2016 | 08 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $530 | $7 | Implemented |
BS0074 # 04 Y:2016 | 04 | 2016 | REPAIR OR REPLACE STEAM TRAPS | $2,326 | $5,073 | Implemented |
BS0074 # 03 Y:2016 | 03 | 2016 | REPLACE BOILER | $2,331 | $14,391 | Implemented |
BS0074 # 02 Y:2016 | 02 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $283 | $448 | Implemented |
BS0074 # 01 Y:2016 | 01 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $249 | $117 | Implemented |
BS0071 # 02 Y:2016 | 02 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $124 | $187 | Implemented |
BS0071 # 04 Y:2016 | 04 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $765 | $2,575 | Implemented |
BS0071 # 03 Y:2016 | 03 | 2016 | INSTALL OCCUPANCY SENSORS | $349 | $660 | Implemented |
BS0071 # 01 Y:2016 | 01 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,181 | $2,633 | Implemented |
BS0070 # 01 Y:2016 | 01 | 2016 | REPAIR OR REPLACE STEAM TRAPS | $13,590 | $12,584 | Implemented |
BS0070 # 03 Y:2016 | 03 | 2016 | PAY UTILITY BILLS ON TIME | $2,153 | $213 | Implemented |