IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,087

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0012 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,155 $700 Implemented
UA0012 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,165 $0 Implemented
UA0011 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $67,624 $122,055 Implemented
UA0011 # 03 Y:2007 03 2007 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $11,081 $0 Implemented
UA0011 # 04 Y:2007 04 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,894 $700 Implemented
UA0010 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,084 $70,481 Implemented
UA0010 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,004 $14,292 Implemented
UA0010 # 04 Y:2007 04 2007 INSTALL TIMERS AND/OR THERMOSTATS $426 $590 Implemented
UA0010 # 05 Y:2007 05 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,616 $700 Implemented
UA0010 # 06 Y:2007 06 2007 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $96 $528 Implemented
UA0010 # 07 Y:2007 07 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $933 $0 Implemented
UA0010 # 08 Y:2007 08 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $155 $320 Implemented
UA0009 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,681 $16,061 Implemented
UA0009 # 02 Y:2007 02 2007 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $588 $0 Implemented
UA0009 # 04 Y:2007 04 2007 INSTALL TIMERS AND/OR THERMOSTATS $600 $236 Implemented
UA0009 # 05 Y:2007 05 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $528 $0 Implemented
UA0009 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $768 $525 Implemented
UA0008 # 02 Y:2007 02 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $11,848 $0 Implemented
UA0008 # 03 Y:2007 03 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $23,233 $1,400 Implemented
UA0008 # 06 Y:2007 06 2007 ADJUST BURNERS FOR EFFICIENT OPERATION $6,248 $200 Implemented
UA0008 # 07 Y:2007 07 2007 ADJUST BURNERS FOR EFFICIENT OPERATION $5,679 $200 Implemented
UA0007 # 01 Y:2007 01 2007 USE PHOTOCELL CONTROLS $1,443 $494 Implemented
UA0007 # 05 Y:2007 05 2007 TURN OFF EQUIPMENT WHEN NOT IN USE $11,900 $0 Implemented
UA0007 # 08 Y:2007 08 2007 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $23,435 $0 Implemented
UA0006 # 04 Y:2007 04 2007 DISCONNECT BALLASTS $497 $216 Implemented