Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,265
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0943 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,211 | $0 | Implemented |
OK0943 # 06 Y:2016 | 06 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $645 | $1,405 | Implemented |
OK0943 # 07 Y:2016 | 07 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,445 | $11,700 | Implemented |
OK0943 # 08 Y:2016 | 08 | 2016 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $5,953 | $4,600 | Implemented |
OK0943 # 09 Y:2016 | 09 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,934 | $2,720 | Implemented |
OK0943 # 10 Y:2016 | 10 | 2016 | INSTALL SET-BACK TIMERS | $1,250 | $790 | Implemented |
OK0943 # 11 Y:2016 | 11 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,334 | $21,372 | Implemented |
OK0943 # 12 Y:2016 | 12 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $861 | $4,032 | Implemented |
OK0942 # 01 Y:2016 | 01 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,767 | $3,112 | Implemented |
OK0942 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $972 | $4,623 | Implemented |
OK0942 # 05 Y:2016 | 05 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $600 | $3,450 | Implemented |
OK0941 # 03 Y:2016 | 03 | 2016 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,497 | $1,960 | Implemented |
OK0941 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,762 | $25,920 | Implemented |
AM0710 # 02 Y:2016 | 02 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,300 | $27 | Implemented |
AM0710 # 03 Y:2016 | 03 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,600 | $1,160 | Implemented |
AM0710 # 04 Y:2016 | 04 | 2016 | PAY UTILITY BILLS ON TIME | $2,944 | $0 | Implemented |
AM0710 # 05 Y:2016 | 05 | 2016 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,635 | $0 | Implemented |
AM0710 # 06 Y:2016 | 06 | 2016 | INSTALL OCCUPANCY SENSORS | $2,170 | $2,100 | Implemented |
AM0709 # 01 Y:2016 | 01 | 2016 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $7,770 | $1,520 | Implemented |
AM0709 # 02 Y:2016 | 02 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,800 | $13,090 | Implemented |
AM0709 # 04 Y:2016 | 04 | 2016 | USE SYNTHETIC LUBRICANT | $2,314 | $0 | Implemented |
AM0708 # 07 Y:2016 | 07 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,290 | $0 | Implemented |
AM0708 # 08 Y:2016 | 08 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,280 | $690 | Implemented |
AM0708 # 09 Y:2016 | 09 | 2016 | PAY UTILITY BILLS ON TIME | $796 | $0 | Implemented |
AM0708 # 10 Y:2016 | 10 | 2016 | USE SYNTHETIC LUBRICANT | $566 | $0 | Implemented |