Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,681
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0287 # 10 Y:2015 | 10 | 2015 | USE PHOTOCELL CONTROLS | $184 | $600 | Implemented |
MI0286 # 01 Y:2015 | 01 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $19,094 | $29,862 | Implemented |
MI0286 # 02 Y:2015 | 02 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $14,710 | $100,350 | Implemented |
MI0285 # 02 Y:2015 | 02 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $22,640 | $52,920 | Implemented |
MI0285 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $15,400 | $80 | Implemented |
MI0285 # 04 Y:2015 | 04 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $13,892 | $76,650 | Implemented |
MI0284 # 01 Y:2015 | 01 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $77,529 | $180,000 | Implemented |
MI0284 # 02 Y:2015 | 02 | 2015 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $28,449 | $55,650 | Implemented |
MI0284 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $28,415 | $160 | Implemented |
MI0284 # 04 Y:2015 | 04 | 2015 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $11,198 | $6,520 | Implemented |
MI0284 # 07 Y:2015 | 07 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,588 | $2,527 | Implemented |
MI0283 # 03 Y:2015 | 03 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $20,030 | $160 | Implemented |
MI0283 # 04 Y:2015 | 04 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,361 | $1,660 | Implemented |
MI0283 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,483 | $9,820 | Implemented |
MI0283 # 08 Y:2015 | 08 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $688 | $639 | Implemented |
MI0282 # 02 Y:2015 | 02 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,822 | $10,322 | Implemented |
MI0282 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,613 | $1,660 | Implemented |
MI0282 # 07 Y:2015 | 07 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,378 | $40 | Implemented |
MI0282 # 08 Y:2015 | 08 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,655 | $1,080 | Implemented |
MI0282 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,303 | $5,120 | Implemented |
MI0282 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,250 | $995 | Implemented |
MI0282 # 11 Y:2015 | 11 | 2015 | USE PHOTOCELL CONTROLS | $197 | $600 | Implemented |
MI0281 # 01 Y:2015 | 01 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,495 | $1,660 | Implemented |
MI0281 # 02 Y:2015 | 02 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $20,275 | $240 | Implemented |
MI0281 # 03 Y:2015 | 03 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $9,053 | $24,488 | Implemented |