IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,075

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0407 # 07 Y:1990 07 1990 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $807 $0 Implemented
TN0404 # 02 Y:1990 02 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,555 $390 Implemented
TN0404 # 04 Y:1990 04 1990 SHUT OFF PILOTS IN STANDBY EQUIPMENT $760 $0 Implemented
TN0404 # 06 Y:1990 06 1990 INSTALL SET-BACK TIMERS $1,258 $0 Implemented
TN0404 # 07 Y:1990 07 1990 USE COMPRESSOR AIR FILTERS $716 $50 Implemented
TN0404 # 08 Y:1990 08 1990 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $195 $0 Implemented
TN0404 # 10 Y:1990 10 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $347 $264 Implemented
TN0402 # 01 Y:1990 01 1990 KEEP LAMPS AND REFLECTORS CLEAN $4,123 $11,116 Implemented
TN0402 # 02 Y:1990 02 1990 INSTALL TIMERS AND/OR THERMOSTATS $2,474 $4,140 Implemented
TN0402 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,428 $960 Implemented
TN0402 # 04 Y:1990 04 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,440 $0 Implemented
TN0402 # 05 Y:1990 05 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $925 $0 Implemented
TN0402 # 06 Y:1990 06 1990 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $880 $500 Implemented
TN0402 # 08 Y:1990 08 1990 DISCONNECT BALLASTS $96 $0 Implemented
TN0403 # 01 Y:1990 01 1990 REDUCE EXCESS STEAM BLEEDING $5,335 $1,280 Implemented
TN0403 # 04 Y:1990 04 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $501 $356 Implemented
TN0403 # 05 Y:1990 05 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $213 $300 Implemented
TN0403 # 06 Y:1990 06 1990 INSTALL SET-BACK TIMERS $532 $0 Implemented
TN0403 # 07 Y:1990 07 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $742 $236 Implemented
TN0403 # 10 Y:1990 10 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $161 $90 Implemented
TN0392 # 02 Y:1990 02 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $5,052 $9,401 Implemented
TN0392 # 03 Y:1990 03 1990 REPAIR AND ELIMINATE STEAM LEAKS $2,222 $4,000 Implemented
TN0392 # 04 Y:1990 04 1990 INSTALL SET-BACK TIMERS $12,329 $0 Implemented
TN0392 # 05 Y:1990 05 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $524 $2,000 Implemented
TN0392 # 06 Y:1990 06 1990 ADJUST VENTS TO MINIMIZE ENERGY USE $10,842 $4,670 Implemented