Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,075
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0387 # 06 Y:1990 | 06 | 1990 | INSULATE BARE EQUIPMENT | $128 | $141 | Implemented |
TN0387 # 07 Y:1990 | 07 | 1990 | INSTALL SET-BACK TIMERS | $359 | $0 | Implemented |
TN0387 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $180 | Implemented |
TN0387 # 09 Y:1990 | 09 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $75 | $0 | Implemented |
TN0387 # 10 Y:1990 | 10 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $15 | $0 | Implemented |
TN0377 # 01 Y:1989 | 01 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $25,781 | $2,304 | Implemented |
TN0377 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $19,212 | $0 | Implemented |
TN0377 # 04 Y:1989 | 04 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,433 | $17,200 | Implemented |
TN0377 # 05 Y:1989 | 05 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $3,364 | $240 | Implemented |
TN0377 # 06 Y:1989 | 06 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,146 | $800 | Implemented |
TN0377 # 07 Y:1989 | 07 | 1989 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $1,960 | $200 | Implemented |
TN0377 # 09 Y:1989 | 09 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,489 | $3,870 | Implemented |
TN0378 # 04 Y:1989 | 04 | 1989 | REPAIR AND ELIMINATE STEAM LEAKS | $2,083 | $540 | Implemented |
TN0378 # 05 Y:1989 | 05 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,802 | $7,500 | Implemented |
TN0378 # 07 Y:1989 | 07 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,301 | $120 | Implemented |
TN0378 # 08 Y:1989 | 08 | 1989 | INSTALL SET-BACK TIMERS | $1,524 | $0 | Implemented |
TN0372 # 01 Y:1989 | 01 | 1989 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $46,225 | $71,400 | Implemented |
TN0372 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,716 | $280 | Implemented |
TN0373 # 01 Y:1989 | 01 | 1989 | OPERATE BOILERS ON HIGH FIRE SETTING | $11,558 | $20,160 | Implemented |
TN0373 # 02 Y:1989 | 02 | 1989 | USE RADIANT HEATER FOR SPOT HEATING | $7,050 | $11,350 | Implemented |
TN0373 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,164 | $180 | Implemented |
TN0373 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $46 | $0 | Implemented |
TN0373 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,599 | $1,800 | Implemented |
TN0373 # 07 Y:1989 | 07 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,407 | $540 | Implemented |
TN0359 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,741 | $2,300 | Implemented |