IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,387

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0454 # 06 Y:1991 06 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,240 $9,000 Implemented
GT0444 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $253 $0 Implemented
GT0444 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $-61 $0 Implemented
GT0444 # 03 Y:1991 03 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $645 $400 Implemented
GT0444 # 04 Y:1991 04 1991 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $780 $800 Implemented
GT0444 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $262 $1,277 Implemented
GT0447 # 01 Y:1991 01 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,880 $500 Implemented
GT0447 # 02 Y:1991 02 1991 INSULATE BARE EQUIPMENT $534 $1,330 Implemented
GT0447 # 03 Y:1991 03 1991 REPAIR AND ELIMINATE STEAM LEAKS $754 $150 Implemented
GT0447 # 04 Y:1991 04 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,147 $5,838 Implemented
GT0447 # 05 Y:1991 05 1991 HEAT WATER WITH EXHAUST HEAT $60,730 $125,000 Implemented
GT0449 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $272 $0 Implemented
GT0449 # 02 Y:1991 02 1991 INSTALL SET-BACK TIMERS $544 $0 Implemented
GT0449 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,960 $1,200 Implemented
GT0449 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $960 $400 Implemented
GT0449 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $200 $750 Implemented
GT0449 # 06 Y:1991 06 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $590 $0 Implemented
GT0449 # 07 Y:1991 07 1991 INSTALL TIMERS AND/OR THERMOSTATS $560 $600 Implemented
GT0441 # 01 Y:1991 01 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,647 $11,262 Implemented
GT0441 # 02 Y:1991 02 1991 INSTALL SET-BACK TIMERS $4,300 $0 Implemented
GT0441 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,427 $0 Implemented
GT0441 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $215 $75 Implemented
GT0441 # 05 Y:1991 05 1991 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $13,000 $15,000 Implemented
GT0441 # 06 Y:1991 06 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,780 $0 Implemented
GT0445 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $484 $129 Implemented