Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,719
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0027 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $545 | $689 | Implemented |
OR0027 # 07 Y:1988 | 07 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $201 | $260 | Implemented |
OR0027 # 08 Y:1988 | 08 | 1988 | OPTIMIZE PLANT POWER FACTOR | $1,092 | $2,730 | Implemented |
OR0027 # 09 Y:1988 | 09 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,684 | $7,740 | Implemented |
OR0027 # 10 Y:1988 | 10 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $31 | $135 | Implemented |
OR0028 # 01 Y:1988 | 01 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,452 | $87 | Implemented |
OR0028 # 02 Y:1988 | 02 | 1988 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $867 | $87 | Implemented |
OR0028 # 03 Y:1988 | 03 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $9,789 | $5,000 | Implemented |
OR0028 # 04 Y:1988 | 04 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $257 | $243 | Implemented |
OR0028 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $362 | $329 | Implemented |
OR0028 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $741 | $1,192 | Implemented |
OR0028 # 08 Y:1988 | 08 | 1988 | OPTIMIZE PLANT POWER FACTOR | $1,129 | $2,550 | Implemented |
OR0023 # 02 Y:1988 | 02 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $374 | $300 | Implemented |
OR0024 # 01 Y:1988 | 01 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $821 | $0 | Implemented |
OR0024 # 03 Y:1988 | 03 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $536 | $300 | Implemented |
OR0024 # 04 Y:1988 | 04 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $146 | $109 | Implemented |
OR0024 # 05 Y:1988 | 05 | 1988 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $6,703 | $6,353 | Implemented |
OR0024 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $38 | $0 | Implemented |
OR0025 # 01 Y:1988 | 01 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $312 | $0 | Implemented |
OR0025 # 02 Y:1988 | 02 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,855 | $300 | Implemented |
OR0025 # 03 Y:1988 | 03 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,627 | $1,502 | Implemented |
OR0025 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $117 | $107 | Implemented |
OR0025 # 06 Y:1988 | 06 | 1988 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $1,519 | $5,000 | Implemented |
OR0025 # 08 Y:1988 | 08 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $283 | $17 | Implemented |
OR0022 # 02 Y:1988 | 02 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $1,762 | $1,250 | Implemented |