Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,686
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0319 # 02 Y:1990 | 02 | 1990 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $6,698 | $1,200 | Implemented |
KU0319 # 03 Y:1990 | 03 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $604 | $400 | Implemented |
KU0319 # 04 Y:1990 | 04 | 1990 | AIR CONDITION ONLY SPACE NECESSARY | $168 | $400 | Implemented |
KU0319 # 05 Y:1990 | 05 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $468 | $360 | Implemented |
KU0319 # 06 Y:1990 | 06 | 1990 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $832 | $487 | Implemented |
KU0319 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,125 | $0 | Implemented |
KU0297 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $218 | $119 | Implemented |
KU0297 # 04 Y:1989 | 04 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $339 | $1,200 | Implemented |
KU0297 # 05 Y:1989 | 05 | 1989 | OPTIMIZE PLANT POWER FACTOR | $7,688 | $13,500 | Implemented |
KU0297 # 06 Y:1989 | 06 | 1989 | TREAT AND REUSE RINSE WATERS | $15,540 | $9,000 | Implemented |
KU0297 # 08 Y:1989 | 08 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $581 | $350 | Implemented |
KU0293 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $227 | $118 | Implemented |
KU0293 # 02 Y:1989 | 02 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $528 | $130 | Implemented |
KU0293 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $360 | $41 | Implemented |
KU0293 # 05 Y:1989 | 05 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,638 | $450 | Implemented |
KU0288 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,193 | $500 | Implemented |
KU0288 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,064 | $1,200 | Implemented |
KU0288 # 03 Y:1989 | 03 | 1989 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $643 | $2,900 | Implemented |
KU0289 # 01 Y:1989 | 01 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,155 | $1,600 | Implemented |
KU0289 # 02 Y:1989 | 02 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,454 | $2,880 | Implemented |
KU0289 # 06 Y:1989 | 06 | 1989 | INSTALL SET-BACK TIMERS | $228 | $40 | Implemented |
KU0292 # 01 Y:1989 | 01 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $10,146 | $800 | Implemented |
KU0292 # 04 Y:1989 | 04 | 1989 | INSTALL SET-BACK TIMERS | $3,496 | $1,000 | Implemented |
KU0292 # 05 Y:1989 | 05 | 1989 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $167 | $120 | Implemented |
KU0256 # 02 Y:1988 | 02 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $7,001 | $0 | Implemented |