Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
777
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0242 # 09 Y:1998 | 09 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $4,922 | $3,036 | Implemented |
ME0241 # 03 Y:1998 | 03 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $14,710 | $12,260 | Implemented |
ME0241 # 04 Y:1998 | 04 | 1998 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $5,602 | $7,719 | Implemented |
ME0241 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,877 | $500 | Implemented |
ME0241 # 06 Y:1998 | 06 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $444 | $804 | Implemented |
ME0241 # 07 Y:1998 | 07 | 1998 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $214 | $250 | Implemented |
ME0241 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,669 | $38,422 | Implemented |
ME0240 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,500 | $33,500 | Implemented |
ME0240 # 03 Y:1998 | 03 | 1998 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,532 | $0 | Implemented |
ME0240 # 05 Y:1998 | 05 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $594 | $550 | Implemented |
ME0240 # 06 Y:1998 | 06 | 1998 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $370 | $400 | Implemented |
ME0240 # 08 Y:1998 | 08 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $827 | $0 | Implemented |
ME0239 # 01 Y:1998 | 01 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $46,878 | $873 | Implemented |
ME0239 # 02 Y:1998 | 02 | 1998 | PAY BILLS ON TIME TO AVOID LATE FEES | $10,701 | $0 | Implemented |
ME0239 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,074 | $239 | Implemented |
ME0239 # 08 Y:1998 | 08 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,164 | $500 | Implemented |
ME0239 # 10 Y:1998 | 10 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $487 | $0 | Implemented |
ME0238 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,607 | $17,669 | Implemented |
ME0238 # 05 Y:1998 | 05 | 1998 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $747 | $2,209 | Implemented |
ME0238 # 07 Y:1998 | 07 | 1998 | PAY UTILITY BILLS ON TIME | $176 | $0 | Implemented |
ME0238 # 08 Y:1998 | 08 | 1998 | PAY UTILITY BILLS ON TIME | $87 | $0 | Implemented |
ME0238 # 10 Y:1998 | 10 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $1,637 | $0 | Implemented |
ME0236 # 02 Y:1998 | 02 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,526 | $27,594 | Implemented |
ME0236 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,300 | $18,666 | Implemented |
ME0235 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,132 | $46,836 | Implemented |