Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,627
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0092 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,081 | $250 | Implemented |
CO0092 # 04 Y:1987 | 04 | 1987 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,490 | $2,000 | Implemented |
CO0092 # 06 Y:1987 | 06 | 1987 | REDUCE VENTILATION AIR | $300 | $36 | Implemented |
CO0092 # 07 Y:1987 | 07 | 1987 | INSULATE BARE EQUIPMENT | $187 | $60 | Implemented |
CO0092 # 08 Y:1987 | 08 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,609 | $10,000 | Implemented |
CO0092 # 09 Y:1987 | 09 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $149 | $525 | Implemented |
CO0092 # 11 Y:1987 | 11 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $2,841 | $474 | Implemented |
CO0092 # 12 Y:1987 | 12 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,813 | $2,762 | Implemented |
CO0087 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,969 | $200 | Implemented |
CO0087 # 02 Y:1987 | 02 | 1987 | REPAIR AND ELIMINATE STEAM LEAKS | $2,954 | $600 | Implemented |
CO0087 # 03 Y:1987 | 03 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $7,174 | $1,000 | Implemented |
CO0087 # 06 Y:1987 | 06 | 1987 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,042 | $0 | Implemented |
CO0087 # 07 Y:1987 | 07 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $421 | $500 | Implemented |
CO0087 # 08 Y:1987 | 08 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,040 | $200 | Implemented |
CO0087 # 10 Y:1987 | 10 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $155 | $347 | Implemented |
CO0087 # 11 Y:1987 | 11 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $586 | $366 | Implemented |
CO0088 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,886 | $2,200 | Implemented |
CO0088 # 04 Y:1987 | 04 | 1987 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $9,431 | $3,200 | Implemented |
CO0088 # 08 Y:1987 | 08 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $982 | $500 | Implemented |
CO0088 # 09 Y:1987 | 09 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,794 | $500 | Implemented |
CO0088 # 11 Y:1987 | 11 | 1987 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,380 | $2,000 | Implemented |
CO0088 # 12 Y:1987 | 12 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,873 | $720 | Implemented |
CO0086 # 01 Y:1987 | 01 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $12,235 | $300 | Implemented |
CO0086 # 02 Y:1987 | 02 | 1987 | REPAIR AND ELIMINATE STEAM LEAKS | $8,294 | $3,331 | Implemented |
CO0086 # 04 Y:1987 | 04 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,419 | $16,669 | Implemented |