Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,052
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0194 # 05 Y:1993 | 05 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,934 | $20,000 | Implemented |
MA0289 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,282 | $20,878 | Implemented |
MA0289 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $486 | $67 | Implemented |
MA0289 # 04 Y:1993 | 04 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,948 | $180 | Implemented |
ME0115 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $965 | $100 | Implemented |
ME0115 # 06 Y:1993 | 06 | 1993 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $25,600 | $2,000 | Implemented |
ME0116 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,946 | $7,000 | Implemented |
ME0116 # 04 Y:1993 | 04 | 1993 | USE PHOTOCELL CONTROLS | $2,907 | $1,200 | Implemented |
ME0117 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $228 | $100 | Implemented |
MO0103 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,408 | $8,467 | Implemented |
MO0103 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,255 | $230 | Implemented |
MO0103 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,379 | $319 | Implemented |
MO0103 # 05 Y:1993 | 05 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,464 | $180 | Implemented |
MO0103 # 07 Y:1993 | 07 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,195 | $1,195 | Implemented |
GT0509 # 02 Y:1993 | 02 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $473 | $0 | Implemented |
GT0509 # 04 Y:1993 | 04 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,370 | $4,820 | Implemented |
GT0509 # 06 Y:1993 | 06 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,569 | $450 | Implemented |
GT0509 # 07 Y:1993 | 07 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,341 | $21,050 | Implemented |
GT0509 # 08 Y:1993 | 08 | 1993 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $281 | $9,800 | Implemented |
SD0068 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $731 | $750 | Implemented |
SD0068 # 02 Y:1993 | 02 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,666 | $17,938 | Implemented |
SD0068 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,035 | $140 | Implemented |
SD0068 # 04 Y:1993 | 04 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $149 | $264 | Implemented |
SD0068 # 05 Y:1993 | 05 | 1993 | REPAIR AND ELIMINATE STEAM LEAKS | $6,065 | $800 | Implemented |
SD0068 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,576 | $1,230 | Implemented |