Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
122
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0651 # 03 Y:2002 | 03 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,142 | $2,300 | n/a |
OK0651 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,926 | $1,360 | n/a |
OK0651 # 09 Y:2002 | 09 | 2002 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $23,400 | $80,000 | n/a |
OK0651 # 10 Y:2002 | 10 | 2002 | IMPROVE SPACE COMFORT CONDITIONING | $46,800 | $2,500 | n/a |
OK0650 # 01 Y:2002 | 01 | 2002 | INSTALL OCCUPANCY SENSORS | $1,203 | $1,190 | Implemented |
OK0651 # 05 Y:2002 | 05 | 2002 | INSTALL SET-BACK TIMERS | $10,697 | $1,416 | n/a |
OK0650 # 02 Y:2002 | 02 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,073 | $100 | Implemented |
OK0651 # 07 Y:2002 | 07 | 2002 | IMPROVE SPACE COMFORT CONDITIONING | $37,907 | $36,300 | n/a |
OK0651 # 04 Y:2002 | 04 | 2002 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $131,274 | $26,000 | n/a |
OK0651 # 08 Y:2002 | 08 | 2002 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $11,700 | $1,350 | n/a |
OK0650 # 04 Y:2002 | 04 | 2002 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $133,632 | $206,750 | Not Implemented |
OK0650 # 03 Y:2002 | 03 | 2002 | USE OPTIMUM THICKNESS INSULATION | $56,715 | $16,956 | n/a |
OK0650 # 05 Y:2002 | 05 | 2002 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $4,021,800 | $30,000,000 | Not Implemented |
OK0651 # 06 Y:2002 | 06 | 2002 | INSTALL OCCUPANCY SENSORS | $741 | $975 | n/a |
OK0651 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,419 | $20,491 | n/a |
OK0650 # 06 Y:2002 | 06 | 2002 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $1,550,000 | $150,000 | Not Implemented |
OK0648 # 05 Y:2002 | 05 | 2002 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $6,955 | $22,000 | Not Implemented |
OK0648 # 10 Y:2002 | 10 | 2002 | COVER OPEN TANKS | $1,983 | $752 | Not Implemented |
OK0648 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,683 | $240 | Implemented |
OK0648 # 01 Y:2002 | 01 | 2002 | USE OPTIMUM THICKNESS INSULATION | $12,108 | $2,317 | Implemented |
OK0648 # 09 Y:2002 | 09 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $169,242 | $37,910 | n/a |
OK0648 # 04 Y:2002 | 04 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,975 | $4,500 | Implemented |
OK0648 # 06 Y:2002 | 06 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $59,232 | $12,200 | n/a |
OK0648 # 02 Y:2002 | 02 | 2002 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $38,422 | $70,536 | Not Implemented |
OK0648 # 08 Y:2002 | 08 | 2002 | INSTALL OCCUPANCY SENSORS | $94 | $288 | Not Implemented |