Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,333
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0477 # 02 Y:2000 | 02 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,290 | $103,000 | Not Implemented |
MA0477 # 03 Y:2000 | 03 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $6,580 | $21,000 | Not Implemented |
MA0477 # 04 Y:2000 | 04 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,910 | $0 | Not Implemented |
MA0477 # 05 Y:2000 | 05 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,200 | $11,700 | Implemented |
MA0477 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $410 | $500 | Implemented |
AR0194 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PLANT POWER FACTOR | $34,500 | $78,525 | Not Implemented |
AR0194 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,287 | $1,089 | Not Implemented |
AR0194 # 03 Y:2000 | 03 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,342 | $6,200 | Not Implemented |
AR0194 # 04 Y:2000 | 04 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $13,959 | $8,000 | Not Implemented |
AR0194 # 05 Y:2000 | 05 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $4,749 | $0 | Not Implemented |
ND0351 # 01 Y:2000 | 01 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,844 | $250 | Not Implemented |
ND0351 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $521 | $1,920 | Not Implemented |
ND0351 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $676 | $450 | Not Implemented |
ND0351 # 04 Y:2000 | 04 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $353 | $100 | Not Implemented |
ND0351 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $195 | $400 | Not Implemented |
ND0351 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $173 | $170 | Not Implemented |
ND0351 # 07 Y:2000 | 07 | 2000 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $715 | $160 | Not Implemented |
ND0351 # 08 Y:2000 | 08 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $285 | $200 | Not Implemented |
ND0351 # 09 Y:2000 | 09 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $282 | $1,672 | Not Implemented |
ND0351 # 10 Y:2000 | 10 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $343 | $400 | Not Implemented |
ND0351 # 11 Y:2000 | 11 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $27 | $40 | Not Implemented |
OR0385 # 01 Y:2000 | 01 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $10,600 | $58,000 | Not Implemented |
OR0385 # 02 Y:2000 | 02 | 2000 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $9,076 | $12,220 | Not Implemented |
OR0385 # 03 Y:2000 | 03 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $7,231 | $600 | Implemented |
OR0385 # 04 Y:2000 | 04 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $3,053 | $0 | Not Implemented |