Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,295
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0252 # 03 Y:2021 | 03 | 2021 | OPTIMIZE PLANT POWER FACTOR | $16,762 | $27,372 | Not Implemented |
IC0252 # 04 Y:2021 | 04 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,533 | $230 | Not Implemented |
UA0247 # 01 Y:2021 | 01 | 2021 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $40,414 | $20,833 | Not Implemented |
UA0247 # 02 Y:2021 | 02 | 2021 | INSTALL OCCUPANCY SENSORS | $314 | $705 | Not Implemented |
UA0247 # 03 Y:2021 | 03 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,372 | $340 | Implemented |
UA0247 # 04 Y:2021 | 04 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,267 | $1,000 | Not Implemented |
UA0247 # 05 Y:2021 | 05 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,460 | $9,801 | Implemented |
UA0247 # 06 Y:2021 | 06 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,313 | $459 | Implemented |
UA0247 # 07 Y:2021 | 07 | 2021 | USE RADIANT HEATER FOR SPOT HEATING | $48,502 | $37,450 | Not Implemented |
IP0151 # 01 Y:2021 | 01 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $759 | $18 | Implemented |
IP0151 # 02 Y:2021 | 02 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,626 | $271 | Implemented |
IP0151 # 03 Y:2021 | 03 | 2021 | INSTALL OCCUPANCY SENSORS | $2,159 | $767 | Implemented |
IP0151 # 04 Y:2021 | 04 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,612 | $34,884 | Implemented |
IP0151 # 05 Y:2021 | 05 | 2021 | REPLACE BOILER | $26,645 | $57,558 | Implemented |
CW0118 # 01 Y:2021 | 01 | 2021 | INSULATE BARE EQUIPMENT | $65,757 | $2,574 | Not Implemented |
CW0118 # 02 Y:2021 | 02 | 2021 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $33,972 | $0 | Not Implemented |
CW0118 # 03 Y:2021 | 03 | 2021 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $331 | $458 | Not Implemented |
CW0118 # 04 Y:2021 | 04 | 2021 | INSTALL OCCUPANCY SENSORS | $479 | $750 | Not Implemented |
CW0118 # 05 Y:2021 | 05 | 2021 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,306 | $0 | Not Implemented |
CW0118 # 06 Y:2021 | 06 | 2021 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $731 | $0 | Not Implemented |
CL2113 # 01 Y:2021 | 01 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $34,351 | $62,500 | n/a |
CL2113 # 02 Y:2021 | 02 | 2021 | MODIFY FACILITY TO AVOID EXCESS MAINTENANCE COSTS | $35,000 | $12,000 | n/a |
CL2113 # 03 Y:2021 | 03 | 2021 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,986 | $400 | n/a |
MZ0320 # 01 Y:2021 | 01 | 2021 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $10,092 | $12,000 | Not Implemented |
MZ0320 # 02 Y:2021 | 02 | 2021 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,821 | $240 | Implemented |