Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0383 # 09 Y:2011 | 09 | 2011 | TREAT AND REUSE RINSE WATERS | $60,914 | $25,231 | Not Implemented |
UM0383 # 10 Y:2011 | 10 | 2011 | HEAT WATER WITH EXHAUST HEAT | $101,682 | $74,000 | Not Implemented |
MA0669 # 01 Y:2011 | 01 | 2011 | REPLACE BOILER | $28,774 | $63,300 | Implemented |
MA0669 # 02 Y:2011 | 02 | 2011 | INSULATE BARE EQUIPMENT | $12,439 | $25,000 | Not Implemented |
MA0669 # 03 Y:2011 | 03 | 2011 | OPTIMIZE PLANT POWER FACTOR | $10,179 | $11,190 | Implemented |
MA0669 # 04 Y:2011 | 04 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,848 | $1,500 | Implemented |
MA0669 # 05 Y:2011 | 05 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,576 | $25,250 | Not Implemented |
MA0669 # 06 Y:2011 | 06 | 2011 | INSULATE BARE EQUIPMENT | $736 | $349 | Not Implemented |
MA0669 # 07 Y:2011 | 07 | 2011 | INSULATE BARE EQUIPMENT | $410 | $550 | Implemented |
LL0344 # 01 Y:2011 | 01 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $15,757 | $630 | Implemented |
LL0344 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,150 | $1,360 | Implemented |
LL0344 # 03 Y:2011 | 03 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,859 | $210 | Implemented |
LL0344 # 04 Y:2011 | 04 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,425 | $575 | Implemented |
LL0344 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $699 | $480 | Implemented |
LL0344 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $151 | $156 | Not Implemented |
WV0424 # 01 Y:2011 | 01 | 2011 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $28,849 | $68,420 | Not Implemented |
WV0424 # 02 Y:2011 | 02 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,755 | $0 | Implemented |
WV0424 # 03 Y:2011 | 03 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,339 | $48 | Implemented |
WV0424 # 04 Y:2011 | 04 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $1,845 | $902 | Implemented |
WV0424 # 05 Y:2011 | 05 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,826 | $1,230 | Not Implemented |
WV0424 # 06 Y:2011 | 06 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $1,463 | $1,000 | Implemented |
WV0424 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,225 | $3,816 | Not Implemented |
WV0424 # 08 Y:2011 | 08 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $733 | $1,600 | Not Implemented |
WV0424 # 09 Y:2011 | 09 | 2011 | INSTALL OCCUPANCY SENSORS | $709 | $592 | Not Implemented |
WV0424 # 10 Y:2011 | 10 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $653 | $395 | Not Implemented |