Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,875
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0255 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $331 | $237 | Not Implemented |
SU0255 # 08 Y:2007 | 08 | 2007 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $14,202 | $19,571 | Not Implemented |
SU0255 # 09 Y:2007 | 09 | 2007 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,084 | $5,590 | Not Implemented |
SU0255 # 10 Y:2007 | 10 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,025 | $32,224 | Not Implemented |
SU0255 # 11 Y:2007 | 11 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $269 | $727 | Not Implemented |
SU0255 # 12 Y:2007 | 12 | 2007 | OPTIMIZE PLANT POWER FACTOR | $563 | $3,344 | Not Implemented |
WV0361 # 01 Y:2007 | 01 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $115,865 | $26,750 | Not Implemented |
WV0361 # 02 Y:2007 | 02 | 2007 | INSULATE BARE EQUIPMENT | $42,691 | $13,780 | Implemented |
WV0361 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $13,999 | $13,900 | Not Implemented |
WV0361 # 04 Y:2007 | 04 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,204 | $2,000 | Implemented |
WV0361 # 05 Y:2007 | 05 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,012 | $15,100 | Not Implemented |
WV0361 # 06 Y:2007 | 06 | 2007 | USE PHOTOCELL CONTROLS | $1,311 | $430 | Implemented |
WV0361 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $0 | Implemented |
WV0361 # 08 Y:2007 | 08 | 2007 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $657 | $276 | Implemented |
SU0251 # 01 Y:2007 | 01 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,054 | $0 | Not Implemented |
SU0251 # 02 Y:2007 | 02 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,682 | $0 | Implemented |
SU0251 # 03 Y:2007 | 03 | 2007 | USE SYNTHETIC LUBRICANT | $707 | $0 | Not Implemented |
SU0251 # 04 Y:2007 | 04 | 2007 | INSTALL SET-BACK TIMERS | $8,210 | $457 | Not Implemented |
SU0251 # 05 Y:2007 | 05 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,670 | $480 | Implemented |
SU0251 # 06 Y:2007 | 06 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $2,314 | $219 | Implemented |
SU0251 # 07 Y:2007 | 07 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $41,420 | $8,140 | Implemented |
SU0251 # 08 Y:2007 | 08 | 2007 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $38,999 | $17,176 | Not Implemented |
SU0251 # 09 Y:2007 | 09 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $14,026 | $5,000 | Implemented |
SU0251 # 10 Y:2007 | 10 | 2007 | INSTALL / REPAIR INSULATION ON STEAM LINES | $278 | $130 | Not Implemented |
SU0251 # 11 Y:2007 | 11 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $234 | $150 | Not Implemented |