IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,431

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0166 # 03 Y:2003 03 2003 INSULATE BARE EQUIPMENT $9,566 $3,733 Not Implemented
LL0166 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,286 $20 Not Implemented
LL0166 # 05 Y:2003 05 2003 USE PHOTOCELL CONTROLS $1,918 $492 Not Implemented
LL0166 # 06 Y:2003 06 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $967 $570 Not Implemented
LL0166 # 07 Y:2003 07 2003 INSTALL OCCUPANCY SENSORS $917 $572 Not Implemented
LL0166 # 08 Y:2003 08 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $55,292 $0 Implemented
LL0163 # 01 Y:2003 01 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,982 $2,560 Not Implemented
LL0163 # 02 Y:2003 02 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,665 $690 Not Implemented
LL0163 # 03 Y:2003 03 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $479 $20 Not Implemented
LL0163 # 04 Y:2003 04 2003 INSTALL OCCUPANCY SENSORS $182 $104 Not Implemented
LL0163 # 05 Y:2003 05 2003 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $4,950 $0 Not Implemented
LL0164 # 01 Y:2003 01 2003 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,006 $225 Not Implemented
LL0164 # 02 Y:2003 02 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $843 $520 Implemented
LL0164 # 03 Y:2003 03 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $520 $270 Not Implemented
LL0164 # 04 Y:2003 04 2003 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $326 $20 Not Implemented
LL0164 # 05 Y:2003 05 2003 INSTALL OCCUPANCY SENSORS $319 $364 Not Implemented
LL0164 # 06 Y:2003 06 2003 USE PHOTOCELL CONTROLS $38 $41 Not Implemented
LL0160 # 01 Y:2003 01 2003 USE PHOTOCELL CONTROLS $50,631 $4,551 Not Implemented
LL0160 # 02 Y:2003 02 2003 INSTALL OCCUPANCY SENSORS $17,563 $5,075 Not Implemented
LL0160 # 03 Y:2003 03 2003 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,307 $10,605 Not Implemented
LL0160 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,909 $1,360 Not Implemented
LL0160 # 05 Y:2003 05 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,798 $900 Not Implemented
LL0160 # 06 Y:2003 06 2003 COMBINE UTILITY METERS $15,037 $0 Not Implemented
LL0160 # 07 Y:2003 07 2003 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,928 $786 Not Implemented
LL0160 # 08 Y:2003 08 2003 COMBINE UTILITY METERS $1,163 $0 Not Implemented