Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0203 # 05 Y:2011 | 05 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,157 | $50 | Implemented |
MI0203 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,006 | $1,320 | Implemented |
UD0831 # 01 Y:2011 | 01 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $28,448 | $196,170 | Not Implemented |
UD0831 # 02 Y:2011 | 02 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,067 | $25,796 | Not Implemented |
UD0831 # 03 Y:2011 | 03 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,392 | $3,863 | Implemented |
UD0831 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $713 | $10,495 | Implemented |
UD0831 # 05 Y:2011 | 05 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,848 | $12,100 | Not Implemented |
UD0831 # 06 Y:2011 | 06 | 2011 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $904 | $1,167 | Not Implemented |
UD0831 # 07 Y:2011 | 07 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $189 | $240 | Implemented |
UD0831 # 08 Y:2011 | 08 | 2011 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $137 | $25 | Implemented |
LL0343 # 01 Y:2011 | 01 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $106,373 | $5,110 | Implemented |
LL0343 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $81,368 | $27,800 | Implemented |
LL0343 # 03 Y:2011 | 03 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $16,390 | $810 | Not Implemented |
LL0343 # 04 Y:2011 | 04 | 2011 | INSULATE BARE EQUIPMENT | $5,155 | $2,526 | Implemented |
LL0343 # 05 Y:2011 | 05 | 2011 | INSTALL SPECTRAL REFLECTORS / DELAMP | $320 | $455 | Implemented |
LL0343 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $368 | $840 | Not Implemented |
LL0343 # 07 Y:2011 | 07 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $363 | $225 | Implemented |
LL0343 # 08 Y:2011 | 08 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $259 | $312 | Not Implemented |
WV0422 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,044 | $18,250 | Not Implemented |
WV0422 # 02 Y:2011 | 02 | 2011 | CHANGE ZONE REHEAT COILS TO VARIABLE AIR VOLUME BOXES | $9,494 | $17,598 | Not Implemented |
WV0422 # 03 Y:2011 | 03 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,167 | $1,000 | Implemented |
WV0422 # 04 Y:2011 | 04 | 2011 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $3,049 | $2,000 | Implemented |
WV0422 # 05 Y:2011 | 05 | 2011 | DEVELOP A REPAIR/REPLACE POLICY | $2,822 | $1,150 | Implemented |
WV0422 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,969 | $920 | Not Implemented |
WV0422 # 07 Y:2011 | 07 | 2011 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $1,500 | $2,875 | Not Implemented |