Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,059
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0407 # 08 Y:2001 | 08 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $289 | $0 | n/a |
WI0406 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,841 | $0 | Implemented |
WI0406 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $7,981 | $14,550 | Not Implemented |
WI0406 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $3,632 | $600 | Not Implemented |
WI0406 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $3,556 | $3,880 | Not Implemented |
WI0406 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $0 | Not Implemented |
WI0406 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,063 | $0 | Not Implemented |
WI0406 # 07 Y:2001 | 07 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $392 | $556 | Not Implemented |
WI0405 # 01 Y:2001 | 01 | 2001 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $5,787 | $4,500 | Implemented |
WI0405 # 02 Y:2001 | 02 | 2001 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,749 | $2,000 | Implemented |
WI0405 # 03 Y:2001 | 03 | 2001 | USE EVAPORATION TO CONCENTRATE MATERIAL | $3,585 | $11,000 | Not Implemented |
WI0405 # 04 Y:2001 | 04 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,138 | $0 | Implemented |
WI0405 # 05 Y:2001 | 05 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,216 | $500 | Implemented |
WI0405 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,839 | $9,403 | Not Implemented |
WI0405 # 07 Y:2001 | 07 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $759 | $0 | Not Implemented |
WI0405 # 08 Y:2001 | 08 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $340 | $640 | Not Implemented |
WI0405 # 09 Y:2001 | 09 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $269 | $570 | Not Implemented |
WI0404 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $798 | $2,400 | Not Implemented |
WI0404 # 04 Y:2001 | 04 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $728 | $1,190 | Not Implemented |
WI0404 # 05 Y:2001 | 05 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $668 | $1,600 | Not Implemented |
WI0404 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $256 | $640 | Not Implemented |
WI0404 # 07 Y:2001 | 07 | 2001 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $135 | $400 | Implemented |
WI0404 # 01 Y:2001 | 01 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $12,000 | $0 | Implemented |
WI0404 # 02 Y:2001 | 02 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,918 | $14,500 | Not Implemented |
WI0403 # 01 Y:2001 | 01 | 2001 | INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM | $82,500 | $120,000 | Not Implemented |