Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,533
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0492 # 04 Y:2005 | 04 | 2005 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $5,832 | $1,000 | Implemented |
WI0492 # 05 Y:2005 | 05 | 2005 | IMPROVE LUBRICATION PRACTICES | $3,033 | $2,155 | Implemented |
WI0492 # 06 Y:2005 | 06 | 2005 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $2,820 | $0 | Not Implemented |
WI0492 # 07 Y:2005 | 07 | 2005 | INSTALL TIMERS AND/OR THERMOSTATS | $1,494 | $600 | Implemented |
WI0492 # 08 Y:2005 | 08 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,335 | $1,280 | Implemented |
WI0492 # 09 Y:2005 | 09 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $665 | $800 | Not Implemented |
UD0719 # 01 Y:2005 | 01 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $41,821 | $11,000 | Not Implemented |
UD0719 # 02 Y:2005 | 02 | 2005 | OPTIMIZE PLANT POWER FACTOR | $25,553 | $24,000 | Not Implemented |
UD0719 # 03 Y:2005 | 03 | 2005 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $13,165 | $20,000 | Implemented |
UD0719 # 04 Y:2005 | 04 | 2005 | OPTIMIZE PLANT POWER FACTOR | $3,580 | $4,800 | Not Implemented |
UD0719 # 05 Y:2005 | 05 | 2005 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,455 | $12,060 | Implemented |
UD0719 # 06 Y:2005 | 06 | 2005 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,173 | $3,498 | Not Implemented |
UD0719 # 07 Y:2005 | 07 | 2005 | DISCONNECT BALLASTS | $1,102 | $75 | Implemented |
UD0719 # 08 Y:2005 | 08 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $583 | $0 | Not Implemented |
UD0719 # 09 Y:2005 | 09 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $583 | $20 | Implemented |
UD0719 # 10 Y:2005 | 10 | 2005 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $485 | $970 | Not Implemented |
UD0719 # 11 Y:2005 | 11 | 2005 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $429 | $0 | Not Implemented |
SU0212 # 01 Y:2005 | 01 | 2005 | PAY BILLS ON TIME TO AVOID LATE FEES | $395 | $0 | Implemented |
SU0212 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,679 | $0 | Implemented |
SU0212 # 03 Y:2005 | 03 | 2005 | USE SYNTHETIC LUBRICANT | $375 | $0 | Implemented |
SU0212 # 04 Y:2005 | 04 | 2005 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $670 | $0 | Not Implemented |
SU0212 # 05 Y:2005 | 05 | 2005 | INSTALL TURBULATORS | $985 | $571 | Not Implemented |
SU0212 # 06 Y:2005 | 06 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,637 | $1,889 | Implemented |
SU0212 # 07 Y:2005 | 07 | 2005 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $12,179 | $10,575 | Not Implemented |
SU0212 # 08 Y:2005 | 08 | 2005 | INSTALL OCCUPANCY SENSORS | $1,966 | $2,792 | Implemented |