Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,754
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0556 # 04 Y:1998 | 04 | 1998 | METER WASTE WATER | $119,889 | $0 | Not Implemented |
OK0556 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,048 | $3,000 | Not Implemented |
OK0556 # 06 Y:1998 | 06 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $633 | $1,020 | Implemented |
OK0556 # 07 Y:1998 | 07 | 1998 | INSTALL SOLID WASTE INCINERATOR FOR HEAT | $1,000 | $0 | Implemented |
OK0555 # 01 Y:1998 | 01 | 1998 | REDESIGN PROCESS | $178,358 | $248,000 | Implemented |
OK0555 # 02 Y:1998 | 02 | 1998 | INSULATE BARE EQUIPMENT | $2,417 | $39,746 | Implemented |
OK0555 # 03 Y:1998 | 03 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $20,281 | $0 | Implemented |
OK0555 # 04 Y:1998 | 04 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,562 | $9,700 | Implemented |
OK0555 # 05 Y:1998 | 05 | 1998 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,911 | $5,543 | Not Implemented |
OK0555 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,825 | $0 | Implemented |
OK0555 # 07 Y:1998 | 07 | 1998 | OPTIMIZE PLANT POWER FACTOR | $6,214 | $1,483 | Not Implemented |
OK0555 # 08 Y:1998 | 08 | 1998 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,557 | $25,000 | Not Implemented |
OK0555 # 09 Y:1998 | 09 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,002 | $320 | Implemented |
OK0555 # 10 Y:1998 | 10 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,823 | $2,100 | Implemented |
OK0555 # 11 Y:1998 | 11 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,573 | $5,000 | Not Implemented |
OK0555 # 12 Y:1998 | 12 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,948 | $1,080 | Not Implemented |
OK0555 # 13 Y:1998 | 13 | 1998 | INSTALL OCCUPANCY SENSORS | $899 | $585 | Not Implemented |
OK0554 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,306 | $13,340 | Not Implemented |
OK0554 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $571 | $2,830 | Implemented |
OK0554 # 03 Y:1998 | 03 | 1998 | INSTALL OCCUPANCY SENSORS | $12,689 | $4,620 | Not Implemented |
OK0554 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $258 | $544 | Not Implemented |
OK0554 # 05 Y:1998 | 05 | 1998 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $17,170 | $97,980 | Not Implemented |
OK0554 # 06 Y:1998 | 06 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $812 | $0 | Implemented |
OK0554 # 07 Y:1998 | 07 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,600 | $0 | Implemented |
OK0554 # 08 Y:1998 | 08 | 1998 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $210,600 | $120,000 | Not Implemented |