IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,708

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0135 # 05 Y:2002 05 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,792 $0 Implemented
LE0135 # 06 Y:2002 06 2002 IMPROVE LUBRICATION PRACTICES $1,066 $200 Implemented
LE0135 # 07 Y:2002 07 2002 OPTIMIZE PLANT POWER FACTOR $62,395 $12,000 Implemented
LE0135 # 08 Y:2002 08 2002 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,654 $630 Implemented
LM0034 # 01 Y:2002 01 2002 INSTALL SPECTRAL REFLECTORS / DELAMP $20,645 $300 Implemented
LM0034 # 02 Y:2002 02 2002 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,353 $1,480 Not Implemented
LM0034 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,937 $200 Not Implemented
LM0034 # 04 Y:2002 04 2002 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,911 $0 Implemented
LM0034 # 05 Y:2002 05 2002 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,006 $2,640 Implemented
LM0034 # 06 Y:2002 06 2002 USE OPTIMUM THICKNESS INSULATION $6,347 $900 Not Implemented
MI0037 # 01 Y:2002 01 2002 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $31,994 $1 Implemented
MI0037 # 02 Y:2002 02 2002 UPGRADE OBSOLETE EQUIPMENT $12,400 $24,000 Implemented
MI0037 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,361 $120 Implemented
MI0037 # 04 Y:2002 04 2002 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $12,505 $1,250 Not Implemented
MI0037 # 05 Y:2002 05 2002 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $2,419 $250 Implemented
MI0037 # 06 Y:2002 06 2002 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS $7,104 $3,545 Not Implemented
LE0134 # 01 Y:2002 01 2002 OPTIMIZE PLANT POWER FACTOR $10,572 $15,000 Not Implemented
LE0134 # 02 Y:2002 02 2002 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $23,457 $1,500 Implemented
LE0134 # 03 Y:2002 03 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,609 $25,249 Implemented
LE0134 # 04 Y:2002 04 2002 INSTALL OCCUPANCY SENSORS $433 $900 Not Implemented
LE0134 # 05 Y:2002 05 2002 MODERATE COOLING TOWER OUTLET TEMPERATURE $1,721 $245 Not Implemented
LE0134 # 06 Y:2002 06 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,676 $1,200 Implemented
SU0135 # 01 Y:2002 01 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $789 $460 Implemented
SU0135 # 02 Y:2002 02 2002 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $23,005 $17,424 Not Implemented
SU0135 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,960 $480 Implemented