Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0593 # 06 Y:2011 | 06 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,860 | $364 | Implemented |
LL0342 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45,311 | $5,360 | Implemented |
LL0342 # 02 Y:2011 | 02 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $9,497 | $1,260 | Not Implemented |
LL0342 # 03 Y:2011 | 03 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,650 | $490 | Implemented |
LL0342 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,560 | $6,685 | Not Implemented |
LL0342 # 05 Y:2011 | 05 | 2011 | USE PHOTOCELL CONTROLS | $186 | $120 | Implemented |
LL0342 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $153 | $167 | Implemented |
LL0342 # 07 Y:2011 | 07 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,351 | $990 | Not Implemented |
LL0342 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $45 | $210 | Implemented |
UA3012 # 01 Y:2011 | 01 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,962 | $6,000 | Not Implemented |
UA3012 # 02 Y:2011 | 02 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $18,630 | $20,000 | Not Implemented |
UA3012 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,047 | $58,885 | Not Implemented |
UA3012 # 04 Y:2011 | 04 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,412 | $4,440 | Not Implemented |
UA3012 # 05 Y:2011 | 05 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $983 | $170 | Implemented |
UA3012 # 06 Y:2011 | 06 | 2011 | INSULATE BARE EQUIPMENT | $8,066 | $30 | Implemented |
UA3012 # 07 Y:2011 | 07 | 2011 | USE OPTIMUM THICKNESS INSULATION | $6,587 | $120 | Implemented |
UM0381 # 01 Y:2011 | 01 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $17,794 | $4,850 | Not Implemented |
UM0381 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,985 | $5,032 | Implemented |
UM0381 # 03 Y:2011 | 03 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,946 | $200 | Not Implemented |
UM0381 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $119 | $600 | Not Implemented |
UM0381 # 05 Y:2011 | 05 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $82 | $10 | Implemented |
UM0381 # 06 Y:2011 | 06 | 2011 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,186 | $1,200 | Not Implemented |
UM0381 # 07 Y:2011 | 07 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,850 | $1,100 | Not Implemented |
UM0381 # 08 Y:2011 | 08 | 2011 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,426 | $3,926 | Not Implemented |
UM0381 # 09 Y:2011 | 09 | 2011 | INSULATE BARE EQUIPMENT | $1,350 | $783 | Not Implemented |