IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,004

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0151 # 07 Y:2015 07 2015 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,970 $4,480 Not Implemented
DL0151 # 08 Y:2015 08 2015 MINIMIZE WATER USAGE $80,640 $200,250 Not Implemented
DL0141 # 01 Y:2015 01 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,650 $5,120 Implemented
DL0141 # 02 Y:2015 02 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $9,730 $8,640 Implemented
DL0141 # 03 Y:2015 03 2015 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $16,965 $960 Implemented
DL0141 # 04 Y:2015 04 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $12,550 $0 Implemented
DL0141 # 05 Y:2015 05 2015 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $33,730 $43,955 Not Implemented
DL0141 # 06 Y:2015 06 2015 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $12,857 $0 Implemented
DL0141 # 07 Y:2015 07 2015 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $3,770 $0 Implemented
DL0141 # 08 Y:2015 08 2015 TURN OFF EQUIPMENT WHEN NOT IN USE $3,410 $0 Not Implemented
DL0141 # 09 Y:2015 09 2015 INSTALL TIMERS AND/OR THERMOSTATS $860 $0 Implemented
DL0133 # 01 Y:2014 01 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $63,690 $134,000 Not Implemented
DL0133 # 02 Y:2014 02 2014 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $11,540 $18,000 Not Implemented
DL0133 # 03 Y:2014 03 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,385 $0 Not Implemented
DL0133 # 04 Y:2014 04 2014 UPGRADE CONTROLS ON COMPRESSORS $7,800 $6,000 Not Implemented
DL0133 # 05 Y:2014 05 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,170 $4,000 Not Implemented
DL0133 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,710 $26,460 Not Implemented
DL0133 # 07 Y:2014 07 2014 INSTALL AUTOMATIC STACK DAMPER $3,680 $550 Not Implemented
DL0133 # 08 Y:2014 08 2014 RECOVER AND REUSE COOLING WATER $5,180 $15,600 Not Implemented
DL0133 # 09 Y:2014 09 2014 REDUCE VENTILATION AIR $1,110 $0 Not Implemented
DL0133 # 10 Y:2014 10 2014 REDUCE VENTILATION AIR $182 $235 Not Implemented
DL0131 # 01 Y:2014 01 2014 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $10,900 $8,500 Not Implemented
DL0131 # 02 Y:2014 02 2014 TREAT AND REUSE RINSE WATERS $13,430 $24,000 Not Implemented
DL0131 # 03 Y:2014 03 2014 RECOVER WASTE HEAT FROM EQUIPMENT $20,280 $40,560 Not Implemented
DL0131 # 04 Y:2014 04 2014 INSTALL AUTOMATIC STACK DAMPER $1,840 $2,800 Not Implemented