Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,708
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0148 # 05 Y:2002 | 05 | 2002 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $9,006 | $3,700 | Implemented |
SU0148 # 06 Y:2002 | 06 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,438 | $320 | Not Implemented |
SU0148 # 07 Y:2002 | 07 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $105 | $0 | Implemented |
SU0148 # 08 Y:2002 | 08 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $70 | $60 | Implemented |
UU0032 # 01 Y:2002 | 01 | 2002 | MOVE BOILER TO MORE EFFICIENT LOCATION | $83 | $86 | Not Implemented |
UU0032 # 02 Y:2002 | 02 | 2002 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,155 | $12,000 | Not Implemented |
UU0032 # 03 Y:2002 | 03 | 2002 | OPTIMIZE PLANT POWER FACTOR | $988 | $2,604 | Not Implemented |
UU0032 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $4,743 | $600 | Not Implemented |
UU0032 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,517 | $17,563 | Not Implemented |
UU0032 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,273 | $343 | Not Implemented |
IC0048 # 01 Y:2002 | 01 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,063 | $0 | Implemented |
IC0048 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $30,279 | $10,600 | Implemented |
IC0048 # 03 Y:2002 | 03 | 2002 | TURN OFF EQUIPMENT WHEN NOT IN USE | $56,765 | $35,050 | Implemented |
IC0048 # 04 Y:2002 | 04 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $71,006 | $3,130 | Not Implemented |
IC0048 # 05 Y:2002 | 05 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $40,640 | $108,000 | Not Implemented |
IC0048 # 06 Y:2002 | 06 | 2002 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $472,157 | $1,500,000 | Not Implemented |
IC0048 # 07 Y:2002 | 07 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $17,986 | $0 | Implemented |
IC0048 # 08 Y:2002 | 08 | 2002 | REDUCE OR ELIMINATE WASTE | $249,587 | $207,024 | Not Implemented |
IC0048 # 09 Y:2002 | 09 | 2002 | AUTOMATE PAYROLL SYSTEM | $364,437 | $18,654 | Not Implemented |
MS0218 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $11,278 | $10,000 | Not Implemented |
MS0218 # 02 Y:2002 | 02 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,569 | $0 | Implemented |
MS0218 # 03 Y:2002 | 03 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $8,686 | $0 | Implemented |
MS0218 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,012 | $284 | Implemented |
MS0218 # 05 Y:2002 | 05 | 2002 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,933 | $1,200 | Not Implemented |
MS0218 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,718 | $0 | Implemented |