IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,230

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SD0432 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $214 $100 Not Implemented
SD0432 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,412 $800 Not Implemented
SD0432 # 05 Y:2011 05 2011 INSTALL OCCUPANCY SENSORS $204 $427 Implemented
SD0432 # 06 Y:2011 06 2011 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $3,408 $8,000 Not Implemented
SD0432 # 07 Y:2011 07 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,373 $8,285 Not Implemented
UD0829 # 01 Y:2011 01 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,457 $10,725 Not Implemented
UD0829 # 02 Y:2011 02 2011 INSTALL SPECTRAL REFLECTORS / DELAMP $2,068 $2,856 Not Implemented
UD0829 # 03 Y:2011 03 2011 INSTALL OCCUPANCY SENSORS $1,862 $313 Not Implemented
UD0829 # 04 Y:2011 04 2011 INSTALL SPECTRAL REFLECTORS / DELAMP $1,711 $1,200 Not Implemented
UD0829 # 05 Y:2011 05 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,046 $3,750 Not Implemented
UD0829 # 06 Y:2011 06 2011 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT $1,738 $5,214 Implemented
UD0829 # 07 Y:2011 07 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,121 $500 Implemented
UD0829 # 08 Y:2011 08 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $547 $500 Implemented
UD0829 # 09 Y:2011 09 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,252 $4,557 Not Implemented
UD0829 # 10 Y:2011 10 2011 ISOLATE HOT OR COLD EQUIPMENT $546 $250 Not Implemented
UD0829 # 11 Y:2011 11 2011 INSTALL FOSSIL FUEL MAKE-UP AIR UNIT $2,189 $9,500 Not Implemented
UD0829 # 12 Y:2011 12 2011 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,647 $25 Not Implemented
UD0829 # 13 Y:2011 13 2011 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $688 $1,500 Not Implemented
UA3010 # 01 Y:2011 01 2011 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $361,004 $66,433 Not Implemented
UA3010 # 02 Y:2011 02 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,810 $17,030 Implemented
UA3010 # 03 Y:2011 03 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,140 $2,925 Implemented
UA3010 # 04 Y:2011 04 2011 USE RADIANT HEATER FOR SPOT HEATING $871 $1,836 Not Implemented
UA3010 # 05 Y:2011 05 2011 INSTALL TIMERS AND/OR THERMOSTATS $1,130 $397 Implemented
UA3010 # 06 Y:2011 06 2011 INSULATE BARE EQUIPMENT $6,592 $499 Not Implemented
UA3010 # 07 Y:2011 07 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $18,662 $50,000 Not Implemented