Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,715
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0083 # 05 Y:2016 | 05 | 2016 | INSULATE BARE EQUIPMENT | $12,261 | $1,680 | Not Implemented |
WM0083 # 06 Y:2016 | 06 | 2016 | INSTALL OCCUPANCY SENSORS | $1,673 | $1,425 | Implemented |
WM0083 # 07 Y:2016 | 07 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,105 | $2,490 | Implemented |
WM0083 # 08 Y:2016 | 08 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $273 | $695 | Not Implemented |
UD0944 # 01 Y:2016 | 01 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,720 | $7,315 | Not Implemented |
UD0944 # 02 Y:2016 | 02 | 2016 | INSULATE BARE EQUIPMENT | $749 | $2,640 | Not Implemented |
UD0944 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $476 | $1,148 | Not Implemented |
UD0944 # 04 Y:2016 | 04 | 2016 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $424 | $0 | Not Implemented |
CO0720 # 01 Y:2016 | 01 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $14,640 | $62,670 | Not Implemented |
CO0720 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,840 | $300 | Implemented |
CO0720 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,190 | $67,155 | Implemented |
CO0720 # 04 Y:2016 | 04 | 2016 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $5,510 | $27,600 | Not Implemented |
CO0720 # 05 Y:2016 | 05 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $930 | $1,330 | Not Implemented |
SF0478 # 01 Y:2016 | 01 | 2016 | USE POWER DURING OFF-PEAK PERIODS | $5,976 | $0 | Implemented |
SF0478 # 02 Y:2016 | 02 | 2016 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $6,324 | $2,354 | Implemented |
SF0478 # 03 Y:2016 | 03 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,559 | $6,856 | Implemented |
SF0478 # 04 Y:2016 | 04 | 2016 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,956 | $2,003 | Not Implemented |
SF0478 # 05 Y:2016 | 05 | 2016 | INSTALL OCCUPANCY SENSORS | $18,801 | $20,415 | Implemented |
SF0478 # 06 Y:2016 | 06 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,062 | $48,543 | Implemented |
SF0478 # 07 Y:2016 | 07 | 2016 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $323,906 | $1,095,380 | Implemented |
LE0414 # 01 Y:2016 | 01 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,057 | $0 | Implemented |
LE0414 # 02 Y:2016 | 02 | 2016 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $34,860 | $36,000 | Implemented |
LE0414 # 03 Y:2016 | 03 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,251 | $1,460 | Not Implemented |
LE0414 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,088 | $14,625 | Implemented |
LE0414 # 05 Y:2016 | 05 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,482 | $10,500 | Implemented |