Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,204
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0232 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,787 | $500 | Not Implemented |
LE0232 # 05 Y:2006 | 05 | 2006 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $3,612 | $620 | Not Implemented |
LE0232 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $809 | $60 | Not Implemented |
LE0232 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $363 | $500 | Not Implemented |
LE0232 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $7,549 | $2,440 | Not Implemented |
LE0232 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,445 | $51,983 | Not Implemented |
MA0600 # 01 Y:2006 | 01 | 2006 | USE UTILITY CONTROLLED POWER MANAGEMENT | $24,000 | $0 | Not Implemented |
MA0600 # 02 Y:2006 | 02 | 2006 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $8,271 | $12,700 | Not Implemented |
MA0600 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,209 | $17,438 | Not Implemented |
MA0600 # 04 Y:2006 | 04 | 2006 | OPTIMIZE PLANT POWER FACTOR | $5,321 | $10,000 | Not Implemented |
MA0600 # 05 Y:2006 | 05 | 2006 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,683 | $2,000 | Not Implemented |
MA0600 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,507 | $5,000 | Not Implemented |
MI0125 # 01 Y:2006 | 01 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $61,073 | $1,290 | Implemented |
MI0125 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,374 | $75,894 | Not Implemented |
MI0125 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $32,634 | $35,000 | Implemented |
MI0125 # 04 Y:2006 | 04 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $24,438 | $1,074 | Implemented |
MI0125 # 05 Y:2006 | 05 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,589 | $850 | Implemented |
MI0125 # 06 Y:2006 | 06 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $6,852 | $4,800 | Not Implemented |
MI0125 # 07 Y:2006 | 07 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,013 | $395 | Implemented |
WI0511 # 01 Y:2006 | 01 | 2006 | AUTOMATE PAYROLL SYSTEM | $10,890 | $6,000 | Not Implemented |
WI0511 # 02 Y:2006 | 02 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $8,256 | $850 | Implemented |
WI0511 # 03 Y:2006 | 03 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,167 | $8,820 | Implemented |
WI0511 # 04 Y:2006 | 04 | 2006 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,712 | $0 | Implemented |
WI0511 # 05 Y:2006 | 05 | 2006 | USE SYNTHETIC LUBRICANT | $2,149 | $0 | Implemented |
WI0511 # 06 Y:2006 | 06 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $446 | $0 | Implemented |