Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,573
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0203 # 06 Y:1998 | 06 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $90,000 | $155,600 | Not Implemented |
UL0204 # 01 Y:1998 | 01 | 1998 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $54,505 | $140,960 | Not Implemented |
UL0204 # 02 Y:1998 | 02 | 1998 | REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT | $162,300 | $0 | Not Implemented |
UL0204 # 03 Y:1998 | 03 | 1998 | ELIMINATE/REDUCE AN OPERATION | $5,360 | $0 | Not Implemented |
ND0315 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,005 | $550 | Not Implemented |
ND0315 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $897 | $840 | Implemented |
ND0315 # 03 Y:1998 | 03 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,863 | $1,000 | Implemented |
ND0315 # 04 Y:1998 | 04 | 1998 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $8,316 | $3,500 | Not Implemented |
ND0315 # 05 Y:1998 | 05 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $431 | $600 | Not Implemented |
ND0315 # 06 Y:1998 | 06 | 1998 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $4,840 | $2,500 | Not Implemented |
ND0315 # 07 Y:1998 | 07 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $56,283 | $38,500 | Not Implemented |
ND0315 # 08 Y:1998 | 08 | 1998 | INSTALL OCCUPANCY SENSORS | $1,206 | $600 | Not Implemented |
ND0315 # 09 Y:1998 | 09 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $23,245 | $500 | Implemented |
ND0313 # 01 Y:1998 | 01 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,085 | $3,000 | n/a |
ND0313 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,421 | $160 | n/a |
ND0313 # 03 Y:1998 | 03 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,879 | $120 | n/a |
ND0313 # 04 Y:1998 | 04 | 1998 | INSTALL OCCUPANCY SENSORS | $838 | $400 | n/a |
ND0313 # 05 Y:1998 | 05 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,403 | $2,500 | n/a |
ND0313 # 06 Y:1998 | 06 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $515 | $825 | n/a |
ND0313 # 07 Y:1998 | 07 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $67 | $0 | n/a |
ND0313 # 08 Y:1998 | 08 | 1998 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $297 | $450 | n/a |
ND0313 # 09 Y:1998 | 09 | 1998 | DEMOLISH OLD BUILDING TO REDUCE TAX AND INSURANCE BILLS | $976 | $250 | n/a |
ND0316 # 01 Y:1998 | 01 | 1998 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $17,390 | $46,000 | Not Implemented |
ND0316 # 02 Y:1998 | 02 | 1998 | AIR CONDITION ONLY SPACE NECESSARY | $8,600 | $37,000 | Not Implemented |
ND0316 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $602 | $80 | Implemented |