Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0590 # 09 Y:1996 | 09 | 1996 | INCREASE AMOUNT OF CONDENSATE RETURNED | $34,612 | $31,200 | Implemented |
MO0178 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $535 | $394 | Implemented |
MO0178 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $892 | $1,216 | Not Implemented |
MO0178 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,595 | $120 | Implemented |
MO0178 # 04 Y:1996 | 04 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,347 | $1,281 | Not Implemented |
MO0178 # 05 Y:1996 | 05 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,106 | $80 | Not Implemented |
OD0057 # 01 Y:1996 | 01 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,833 | $500 | Implemented |
OD0057 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,120 | $600 | Implemented |
OD0057 # 03 Y:1996 | 03 | 1996 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,630 | $1,950 | Implemented |
OD0057 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,768 | $430 | Implemented |
OD0057 # 05 Y:1996 | 05 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,639 | $4,232 | Not Implemented |
OD0057 # 06 Y:1996 | 06 | 1996 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $751 | $200 | Not Implemented |
MO0178 # 06 Y:1996 | 06 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $268 | $0 | Implemented |
MO0178 # 07 Y:1996 | 07 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,458 | $3,003 | Not Implemented |
MO0178 # 08 Y:1996 | 08 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $4,000 | $8,000 | Not Implemented |
AS0180 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,604 | $0 | Not Implemented |
AS0180 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,978 | $14,977 | Implemented |
AS0180 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $2,295 | $1,350 | Not Implemented |
AS0180 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,307 | $9,177 | Not Implemented |
AS0180 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,240 | $5,343 | Not Implemented |
AS0180 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $63,244 | $50,000 | Implemented |
AS0180 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,003 | $0 | Not Implemented |
AS0180 # 08 Y:1996 | 08 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $391 | $320 | Not Implemented |
AS0180 # 09 Y:1996 | 09 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,648 | $30 | Implemented |
AS0180 # 10 Y:1996 | 10 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $330 | $30 | Implemented |