Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,996
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0180 # 08 Y:1997 | 08 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $87,880 | $0 | Not Implemented |
UF0180 # 09 Y:1997 | 09 | 1997 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $2,127 | $3,006 | Not Implemented |
UF0180 # 10 Y:1997 | 10 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,794 | $0 | Implemented |
MS0087 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $5,870 | $1,500 | Implemented |
MS0087 # 02 Y:1997 | 02 | 1997 | DISCONNECT BALLASTS | $313 | $150 | Implemented |
MS0087 # 03 Y:1997 | 03 | 1997 | USE SYNTHETIC LUBRICANT | $1,944 | $275 | Implemented |
MS0087 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,232 | $7,102 | Implemented |
MS0087 # 05 Y:1997 | 05 | 1997 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,607 | $561 | Implemented |
MS0087 # 06 Y:1997 | 06 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,564 | $11,519 | Not Implemented |
MS0087 # 07 Y:1997 | 07 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,400 | $0 | Implemented |
MS0087 # 08 Y:1997 | 08 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $46,844 | $20,800 | Not Implemented |
NV0079 # 01 Y:1997 | 01 | 1997 | INSULATE BARE EQUIPMENT | $8,890 | $9,124 | Not Implemented |
NV0079 # 02 Y:1997 | 02 | 1997 | INSULATE BARE EQUIPMENT | $13,870 | $7,320 | Not Implemented |
NV0079 # 03 Y:1997 | 03 | 1997 | REPAIR AND ELIMINATE STEAM LEAKS | $1,071 | $250 | Implemented |
NV0079 # 04 Y:1997 | 04 | 1997 | INSULATE BARE EQUIPMENT | $325 | $409 | Implemented |
NV0079 # 05 Y:1997 | 05 | 1997 | INSTALL OCCUPANCY SENSORS | $896 | $196 | Not Implemented |
NV0079 # 06 Y:1997 | 06 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,129 | $3,350 | Not Implemented |
NV0079 # 07 Y:1997 | 07 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $137 | $10 | Implemented |
NV0079 # 08 Y:1997 | 08 | 1997 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $840 | $408 | Not Implemented |
NV0079 # 09 Y:1997 | 09 | 1997 | PAY BILLS ON TIME TO AVOID LATE FEES | $2,350 | $0 | Not Implemented |
ME0220 # 01 Y:1997 | 01 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,092 | $1,000 | n/a |
ME0220 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,316 | $500 | n/a |
ME0220 # 03 Y:1997 | 03 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $759 | $400 | n/a |
ME0220 # 04 Y:1997 | 04 | 1997 | PAY UTILITY BILLS ON TIME | $852 | $0 | n/a |
ME0220 # 05 Y:1997 | 05 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $457 | $763 | n/a |