IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,996

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0180 # 08 Y:1997 08 1997 RECOVER AND REUSE WASTE MATERIAL $87,880 $0 Not Implemented
UF0180 # 09 Y:1997 09 1997 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $2,127 $3,006 Not Implemented
UF0180 # 10 Y:1997 10 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,794 $0 Implemented
MS0087 # 01 Y:1997 01 1997 OPTIMIZE PLANT POWER FACTOR $5,870 $1,500 Implemented
MS0087 # 02 Y:1997 02 1997 DISCONNECT BALLASTS $313 $150 Implemented
MS0087 # 03 Y:1997 03 1997 USE SYNTHETIC LUBRICANT $1,944 $275 Implemented
MS0087 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,232 $7,102 Implemented
MS0087 # 05 Y:1997 05 1997 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $1,607 $561 Implemented
MS0087 # 06 Y:1997 06 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,564 $11,519 Not Implemented
MS0087 # 07 Y:1997 07 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,400 $0 Implemented
MS0087 # 08 Y:1997 08 1997 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $46,844 $20,800 Not Implemented
NV0079 # 01 Y:1997 01 1997 INSULATE BARE EQUIPMENT $8,890 $9,124 Not Implemented
NV0079 # 02 Y:1997 02 1997 INSULATE BARE EQUIPMENT $13,870 $7,320 Not Implemented
NV0079 # 03 Y:1997 03 1997 REPAIR AND ELIMINATE STEAM LEAKS $1,071 $250 Implemented
NV0079 # 04 Y:1997 04 1997 INSULATE BARE EQUIPMENT $325 $409 Implemented
NV0079 # 05 Y:1997 05 1997 INSTALL OCCUPANCY SENSORS $896 $196 Not Implemented
NV0079 # 06 Y:1997 06 1997 RECOVER WASTE HEAT FROM EQUIPMENT $3,129 $3,350 Not Implemented
NV0079 # 07 Y:1997 07 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $137 $10 Implemented
NV0079 # 08 Y:1997 08 1997 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $840 $408 Not Implemented
NV0079 # 09 Y:1997 09 1997 PAY BILLS ON TIME TO AVOID LATE FEES $2,350 $0 Not Implemented
ME0220 # 01 Y:1997 01 1997 RECOVER WASTE HEAT FROM EQUIPMENT $4,092 $1,000 n/a
ME0220 # 02 Y:1997 02 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,316 $500 n/a
ME0220 # 03 Y:1997 03 1997 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $759 $400 n/a
ME0220 # 04 Y:1997 04 1997 PAY UTILITY BILLS ON TIME $852 $0 n/a
ME0220 # 05 Y:1997 05 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $457 $763 n/a