Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,703
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0445 # 04 Y:2014 | 04 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,993 | $21,342 | Implemented |
SF0445 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,822 | $90,352 | Not Implemented |
MZ0136 # 01 Y:2014 | 01 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $16,626 | $290 | Implemented |
MZ0136 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $672 | $1,600 | Implemented |
MZ0136 # 03 Y:2014 | 03 | 2014 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $282 | $50 | Implemented |
MZ0136 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,785 | $18,300 | Implemented |
MZ0136 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $16,863 | $910 | Implemented |
MZ0136 # 06 Y:2014 | 06 | 2014 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,112 | $2,840 | Not Implemented |
MZ0136 # 07 Y:2014 | 07 | 2014 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $13,943 | $63,000 | Not Implemented |
MZ0136 # 08 Y:2014 | 08 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $44,793 | $7,900 | Not Implemented |
MZ0136 # 09 Y:2014 | 09 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,564 | $0 | Not Implemented |
AM0653 # 01 Y:2014 | 01 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,090 | $47,700 | Implemented |
AM0653 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16,460 | $26 | Implemented |
AM0653 # 03 Y:2014 | 03 | 2014 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $14,200 | $600 | Not Implemented |
AM0653 # 04 Y:2014 | 04 | 2014 | USE SYNTHETIC LUBRICANT | $12,640 | $0 | Not Implemented |
AM0653 # 05 Y:2014 | 05 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $9,860 | $7,200 | Not Implemented |
AM0653 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,015 | $2,000 | Implemented |
AM0653 # 07 Y:2014 | 07 | 2014 | KEEP LAMPS AND REFLECTORS CLEAN | $5,940 | $1,305 | Not Implemented |
AM0653 # 08 Y:2014 | 08 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $1,090 | $1,160 | Implemented |
OR0626 # 01 Y:2014 | 01 | 2014 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $18,202 | $6,792 | Not Implemented |
OR0626 # 02 Y:2014 | 02 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,945 | $1,000 | Not Implemented |
OR0626 # 03 Y:2014 | 03 | 2014 | IMPROVE COMBUSTION CONTROL CAPABILITY | $11,422 | $7,219 | Not Implemented |
OR0626 # 04 Y:2014 | 04 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $7,138 | $5,500 | Not Implemented |
OR0626 # 05 Y:2014 | 05 | 2014 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $5,445 | $6,461 | Not Implemented |
OR0626 # 06 Y:2014 | 06 | 2014 | INSULATE BARE EQUIPMENT | $3,138 | $5,659 | Not Implemented |