Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,105
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0669 # 12 Y:2003 | 12 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,847 | $1,754 | Not Implemented |
UD0669 # 13 Y:2003 | 13 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,888 | $6,450 | Implemented |
UD0669 # 14 Y:2003 | 14 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,679 | $142 | Implemented |
UD0669 # 15 Y:2003 | 15 | 2003 | INSTALL OCCUPANCY SENSORS | $1,622 | $177 | Not Implemented |
UD0669 # 16 Y:2003 | 16 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $568 | $1,026 | Implemented |
UD0669 # 17 Y:2003 | 17 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $350 | $1,168 | Not Implemented |
UM0232 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,492 | $5,655 | Not Implemented |
UM0232 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $42,683 | $2,100 | Implemented |
UM0232 # 03 Y:2003 | 03 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,416 | $10,600 | Not Implemented |
UM0232 # 04 Y:2003 | 04 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,706 | $1,660 | Not Implemented |
UM0232 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $13,693 | $1,000 | Implemented |
UM0232 # 06 Y:2003 | 06 | 2003 | INSTALL COMMON HEADER ON COMPRESSORS | $13,700 | $6,480 | Implemented |
WI0443 # 01 Y:2003 | 01 | 2003 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $3,583 | $9,000 | Implemented |
WI0443 # 02 Y:2003 | 02 | 2003 | REDUCE EXCESSIVE BOILER BLOWDOWN | $1,964 | $4,500 | Implemented |
WI0443 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,215 | $500 | Implemented |
WI0443 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $843 | $2,500 | Not Implemented |
WI0443 # 05 Y:2003 | 05 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $421 | $640 | Implemented |
WI0443 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $341 | $75 | Implemented |
LM0056 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,587 | $690 | Implemented |
LM0056 # 02 Y:2003 | 02 | 2003 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,713 | $0 | Implemented |
LM0056 # 03 Y:2003 | 03 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,371 | $1,200 | Not Implemented |
LM0056 # 04 Y:2003 | 04 | 2003 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $300,000 | $5,000 | Not Implemented |
LM0056 # 05 Y:2003 | 05 | 2003 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $450,000 | $20,000 | n/a |
LM0056 # 06 Y:2003 | 06 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,754 | $1,968 | Not Implemented |
LM0056 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,330 | $6,675 | Not Implemented |