Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,130
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0081 # 08 Y:1993 | 08 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,199 | $4,250 | Implemented |
OK0399 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $662 | $0 | Implemented |
OK0399 # 02 Y:1993 | 02 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $133 | $452 | Not Implemented |
OK0399 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,239 | $3,560 | Implemented |
OK0399 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $829 | $546 | Implemented |
OK0399 # 05 Y:1993 | 05 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,137 | $0 | Implemented |
OK0399 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,418 | $10,680 | Implemented |
OK0399 # 07 Y:1993 | 07 | 1993 | INSTALL OCCUPANCY SENSORS | $416 | $100 | Not Implemented |
OK0399 # 08 Y:1993 | 08 | 1993 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $743 | $880 | Implemented |
OK0399 # 09 Y:1993 | 09 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $644 | $0 | Implemented |
OK0399 # 10 Y:1993 | 10 | 1993 | USE POWER DURING OFF-PEAK PERIODS | $10,811 | $0 | Not Implemented |
OK0399 # 11 Y:1993 | 11 | 1993 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,570 | $0 | Not Implemented |
OR0170 # 01 Y:1993 | 01 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $10,430 | $750 | Implemented |
OR0170 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $831 | $2,940 | Implemented |
OR0170 # 03 Y:1993 | 03 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,875 | $0 | Implemented |
OR0170 # 04 Y:1993 | 04 | 1993 | KEEP BOILER TUBES CLEAN | $1,644 | $1,000 | Implemented |
OR0170 # 05 Y:1993 | 05 | 1993 | OPTIMIZE PLANT POWER FACTOR | $6,396 | $6,750 | Implemented |
OR0170 # 06 Y:1993 | 06 | 1993 | RECOVER AND REUSE COOLING WATER | $5,728 | $20,750 | Not Implemented |
OR0170 # 07 Y:1993 | 07 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $391 | $1,519 | Implemented |
OR0170 # 08 Y:1993 | 08 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,648 | $6,800 | Not Implemented |
SD0050 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,856 | $2,993 | Implemented |
SD0050 # 02 Y:1993 | 02 | 1993 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $178 | $214 | Implemented |
SD0050 # 03 Y:1993 | 03 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,464 | $0 | Implemented |
SD0050 # 04 Y:1993 | 04 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,354 | $25,076 | Implemented |
SD0050 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,393 | $3,521 | Not Implemented |