Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,703
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0254 # 05 Y:2014 | 05 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $11,159 | $2,206 | Not Implemented |
MI0254 # 06 Y:2014 | 06 | 2014 | OPTIMIZE PLANT POWER FACTOR | $5,083 | $7,680 | Implemented |
MI0254 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,680 | $2,160 | Implemented |
MI0254 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,949 | $13,170 | Implemented |
MI0254 # 09 Y:2014 | 09 | 2014 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $3,341 | $600 | Not Implemented |
MI0254 # 10 Y:2014 | 10 | 2014 | INSTALL OCCUPANCY SENSORS | $3,162 | $800 | Implemented |
MI0254 # 11 Y:2014 | 11 | 2014 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,914 | $520 | Not Implemented |
MI0254 # 12 Y:2014 | 12 | 2014 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,523 | $240 | Implemented |
MI0254 # 13 Y:2014 | 13 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $727 | $1,660 | Implemented |
MI0254 # 14 Y:2014 | 14 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $447 | $80 | Implemented |
DL0123 # 01 Y:2014 | 01 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,760 | $0 | Implemented |
DL0123 # 02 Y:2014 | 02 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,240 | $0 | Not Implemented |
DL0123 # 03 Y:2014 | 03 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,740 | $8,382 | Implemented |
DL0123 # 04 Y:2014 | 04 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,880 | $547 | Implemented |
DL0123 # 05 Y:2014 | 05 | 2014 | AIR CONDITION ONLY SPACE NECESSARY | $1,250 | $0 | Implemented |
DL0123 # 06 Y:2014 | 06 | 2014 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,900 | $0 | Implemented |
DL0123 # 07 Y:2014 | 07 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $990 | $200 | Implemented |
DL0123 # 08 Y:2014 | 08 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $350 | $0 | Implemented |
DL0123 # 09 Y:2014 | 09 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $780 | $200 | Not Implemented |
DL0123 # 10 Y:2014 | 10 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $1,560 | $400 | Implemented |
DL0123 # 11 Y:2014 | 11 | 2014 | USE RADIANT HEATER FOR SPOT HEATING | $2,610 | $2,610 | Implemented |
DL0123 # 12 Y:2014 | 12 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $14,200 | $0 | Implemented |
SU0359 # 01 Y:2014 | 01 | 2014 | INSULATE FEEDWATER TANK | $1,037 | $137 | Implemented |
SU0359 # 02 Y:2014 | 02 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,651 | $1,900 | Implemented |
SU0359 # 03 Y:2014 | 03 | 2014 | INSTALL OCCUPANCY SENSORS | $1,346 | $470 | Implemented |